User's Manual

GB
12
COMMON FEATURES FOR ALL MODELS
WITH ELECTRIC HOTPLATES AND AUTO-
MATIC IGNITION
The supply voltage and frequency will be
as shown on the rating plate.
If an electric hotplate gets cracked, the
hob should be disconnected from the elec-
tricity supply.
COMMON FEATURES FOR ALL
MODELS WITH GAS BURNERS
Warnings:
a) Before installation, make sure that the
local supply conditions (the gas type and
pressure) are compatible with the applian-
ces setup.
b) The setup conditions for this appliance
are written on the label (or the rating
plate).
c) This appliance should not be connected
to a device for removing combustion pro-
ducts. It should be installed and connected
in compliance with the current installation
standards. Special attention should be paid
to the regulations applying to ventilation.
A gas cooking appliance produces
heat and moisture at the site where it is
installed. The kitchen should be provi-
ded with suitable ventilation: natural
ventilation sources should be kept
clear, a window opened, or an effective
mechical ventilation system device,
such as a hood, installed.
The intense and prolonged use of
the appliance may call for complemen-
tary ventilation, such as opening a win-
dow, or more efficient ventilation such
as increasing the power of the mecha-
nical ventilation if this exists.
Class 3 hob.
You should keep the Guaran-
tee Certificate or, where relevant, the
technical datasheet, together with
the Instruction Manual for the dura-
tion of the service life of the applian-
ce. It has important technical infor-
mation about the appliance.
Technical details
Country
Spain
Portugal
United Kingdom
Switzerland
Ireland
Chez Republic
Greece
Hungary
Denmark
Norway
Finland
Sweden
Category
II2H3+
II2H3+
II2H3+
II2H3+
II2H3+
II2H3+
I3+
I2H
I2H
I2H
I2H
I2H
Table 2
Table 3
Semi-rapid
1.75
0.17
0.13
0.13
0.47
>52
Burner
Nominal Calorific Consumption
Nominal consumption*
Reduced calorific consumption
Performance
* Consumption over Gross Calorific Value (H )
Auxiliary
1
0.10
0.07
0.07
0.33
-
Rapid
3
0.29
0.22
0.21
0.77
>52
s
Triple crown
3.8
0.36
0.28
0.27
1.55
>52
kW
G-20 (Nm
3
/h)
G-30 (Kg/h)
G-31 (Kg/h)
mbar
20
29
37
kW
%