User's Manual

GB
7
Important
INSTALLATION AND SETUP SHOULD
BE CARRIED OUT BY AN AUTHORISED
TECHNICIAN IN LINE WITH CURRENT
INSTALLATION STANDARDS.
A gap with the dimensions shown in figure
1 will be cut into the worktop or stove.
The system for fixing the hob is intended
for use with kitchen units with a thickness
of 20, 30 or 40 mm.
In free-standing models, a shelf should be
placed inside the unit. The minimum dis-
tance between the lower part of the hob
and the upper part of the shelf should be
20 mm.
The hobs described in this manual can
only be installed with TEKA ovens.
The minimum distance between the surfa-
ce supporting the cooking pans and the
lower part of the kitchen unit or the hood
located above the hob should be 650 mm.
If the hoods installation instructions recom-
mend that the gap is greater than this, you
should follow this advice.
The unit where the hob and oven will be
located will be suitably fixed.
When hobs are handled before
being installed, care should be taken in
case there is any protruding part or
sharp edge which could cause injury.
TEKA does not accept liability for
any malfunction or damage that may be
caused by faulty installation.
The glues used in manufacturing
the kitchen unit and in the adhesive on
the decorative laminate of the worktop
surface should be made to tolerate tem-
peratures of up to 100ºC.
Installation
Positioning the hobs
fig. 1
Minimum distances
to walls
Minimum ventilation
distances
Installation
space
40 mm minimum
40 mm minimum
OVEN
m
a
x
i
m
u
m