User's Manual

Eco Water Monitor User Manual
9 | P a g e
9-5939-02
4.7 Dimensions (Monitor)
120mm x 90mm x 50mm / 4.72’’ x 3.54’’ x 1.96’’
4.8 Power Supply
- Tekelek Eco-Water Sensor3V LiMn cell, CR2450 or CR2430 (Depending on sensor)
- Tekelek Eco-Water Monitor:
- Receiver: 5V DC (40mA)
- Backup battery: 3V LiMn cell, CR2450 or CR2430
4.9 Mains Power Supply (incl.) for Tekelek Eco-Water Monitor
North America: 110V +/- 10% 60Hz, meets UL60950-1
Other: 150V-240V, 50-60 Hz, meets EN60950-1
4.10 Battery Life
Tekelek Eco-Water Sensor: 5 years (estimated life)
Tekelek Eco-Water Monitor Receiver memory back-up battery: 3yr if device is not plugged in**
4.11 Max and Min Operation (Sensor)
Operating temperature range: -20°C/-4°F to +60°C/140°F
Operating Humidity: 15 - 95% non-condensing
4.12 Max and Min Operation (Monitor)
Operating temperature range: 0°C/32°F to +50°C/122°F
Operating Humidity: 0 - 95% non-condensing
4.13 Hole size for fitting sensor:
32mm/1.25inch diameter
* The Tekelek Eco Level Sensor and Tekelek Eco-Water Monitor bar-graph displays may differ (see Display
symbol reference table).
** This device contains a small battery to keep time during power cuts. If the device is left unpowered for an
extended period, then the battery will deplete.