Installation
  3 of 4   © 2007   D 479 - 05/07
Error Messages
Error Messages & Troubleshooting
Applications using Multiple User Switches
Multiple User Switches can be used together when:
1)  For convenience, User Switches are required at different 
locations.
2) Scenes other than the three pre-programmed scenes 
in the 479 are requried. In this case, a 480 or 481 User 
Switch can be added.
Symptom Cause Corrective Action
3 Buttons 
Flashing Red
Away
User Switch 
disconnected from 
tN4 bus.
• 
•  Check tN4 and common 
wires for loose wire 
connections.
• 
•  Ensure the tN4 controls have 
power.
• 
•  Check R and C wires for 
correct polarity.
Each tN4 bus cannot exceed 24 devices. Devices include 
thermostats, setpoint controls, mixing expansion modules, 
and user switches.
When using multiple User Switches at the same location, 
they can be installed adjacent to each other in the same 
switch box.