4 Operations, Alarms, and Management
4.1 Configuration
The Breeze/Breeze-V/Vivid+ supports a full range of Over-the-Air (OTA) configuration options.
Specific technical details are available in the Breeze/Breeze-V/Vivid+ Technical Reference
Manual [3]. All configuration commands need to be sent OTA during a sensor’s downlink
windows.
4.2 Default Configuration
If dynamic reporting mode is enabled, the default configuration of the Breeze/Breeze-V/Vivid+
is as shown in Table 4-1. If dynamic reporting mode is not enabled, the Sensor will act as if it is
exclusively in active mode.
Table 4-1: Breeze/Breeze-V/Vivid+ Default Reporting Behavior
Parameter
Report
Destination
Default Reporting Frequency
During Active Mode
During Inactive Mode
Remaining Battery
Capacity of the Sensor
NS and Display
Every 5 (five) minutes
Every 1 (one) hour
Remaining Battery
Capacity of the Display
NS and Display
Every 5 (five) minutes
Every 1 (one) hour
Ambient Temperature
NS and Display
Every 5 (five) minutes
Every 1 (one) hour
Ambient Relative
Humidity
NS and Display
Every 5 (five) minutes
Every 1 (one) hour
CO2 Concentration
NS and Display
Every 5 (five) minutes
Every 1 (one) hour
Pressure
NS only
Every 5 (five) minutes
Every 1 (one) hour
Motion
NS only
Report motion after 1 (one)
PIR event
Clear motion after 5 (five)
minutes of no motion
Report motion after 1 (one)
PIR event
Clear motion after 5 (five)
minutes of no motion
Note:
CO
2
concentration and pressure are reported by Breeze and Breeze-V models only. For
the Vivid+ model, the Sensor will update the Display such that the CO
2
concentration
field will be blank.
Motion is reported by Vivid+ and Breeze-V models only.