User's Manual

Tutorial
GB1400 User Manual 2-33
B. Locate the controls in the PATTERN box of the Generator. Make sure the
PRBS button is enabled (the LED inside this switch should be ON). Set the
Generator pattern to a 2
23
-1 bit PRBS as follows:
Set this parameter …to this value …using this procedure.
PRBS type PN 23 Press pattern up/down arrow keys until
PATTERN is set to PN 23
C. Locate the controls in the ERROR INJECT box of the Generator. Verify
that the Generator ERROR RATE GENERATOR is OFF (the LED within the switch should
be OFF). If the LED in the error inject RATE key is ON, then press RATE one or
more times until it turns off.
4. Setup Analyzer for “AUTO-SEARCH” Operation.
A. Locate the controls in the SYNC box of the Analyzer. Verify that the
Analyzer AUTO SEARCH function is ENABLED. The LED in the AUTO SEARCH key
should be ON. If the LED is OFF, press the AUTO SEARCH function one time until
the LED is ON. At this point, verify that the green LOCK LED is ON.
B. Locate the controls in the ERROR DETECTION box of the Analyzer. Zero
all Analyzer error counts by pressing the CLEAR key. Confirm that the number of
errors and the error rate were reset to 0 (note: error rate will start changing as
more and more bits are received. After several minutes of operation, the error
rate should reach 0.0E-9 0.0E-10 0.0E-11 and on).
C. Locate the controls in the ERROR HISTORY box of the Analyzer. Reset all
Analyzer history LEDs by pressing this CLEAR key. Confirm that all ERROR
HISTORY LED’s are turned OFF.
D. Locate the controls in the ERROR INJECT box of the Generator. Verify the
GB1400 Analyzer can detect errors by pressing the Generator ERROR INJECT
SINGLE key several times. Verify that the number of errors count displayed by
the Analyzer increments each time the Generator SINGLE key is pressed.
In effect you are now performing a bit error rate test on the test cables connecting
the gigaBERT1400 Generator and Analyzer. In an actual BER test,
gigaBERT1400 Generator clock and data outputs would be connected to inputs
on a "device under test" (DUT) while gigaBERT1400 Analyzer inputs would be
connected to outputs on the DUT.