OSCILLOSCOPE SELECTION GUIDE
OSCILLOSCOPE SELECTION GUIDE OSCILLOSCOPE SELECTOR GUIDE Tektronix offers oscilloscopes for many different applications and uses. To help you choose the right scope for your needs, the most common criteria for selecting a scope are listed below, along with helpful tips for determining your requirements. 1 Bandwidth All oscilloscopes have a low-pass frequency response that rolls off at higher frequencies.
OSCILLOSCOPE SELECTION GUIDE CHOOSING YOUR OSCILLOSCOPE Engineers, technicians and educators all have different workloads, different measurement needs, and different environments. To meet your needs Tektronix offers a wide range of oscilloscopes. This guide gives an overview of the various types of oscilloscopes currently available, along with high-level specifications that you can use for comparison. If you need a refresher on oscilloscope specifications, download the XYZs of Oscilloscopes Primer.
OSCILLOSCOPE SELECTION GUIDE 5 Series MSO The most flexible, configurable and easy-to-use oscilloscope that delivers the fastest time-to-insight to designers and technicians developing modern embedded systems, by providing FlexChannel technology, 5-in-1 instrument integration, and a next-generation user interface.
OSCILLOSCOPE SELECTION GUIDE MIXED SIGNAL AND MIXED DOMAIN OSCILLOSCOPES MSO/DPO2000B MDO3000 Channels 2, 4 analog channels; 16 digital channels (MSO2000B) 2, 4 analog channels; 16 digital channels (MDO3MSO option) 1 spectrum analyzer input 1 Arbitrary/Function Generator (MDO3AFG option) Bandwidth 70 MHz to 200 MHz 100 MHz to 1 GHz Spectrum Analyzer Frequency Range — Standard: 9 kHz to Analog Bandwidth Optional: 9 kHz to 3 GHz Sample Rate 1 GS/s (analog); 1 GS/s (digital, only 1 pod); 500 MS/s
OSCILLOSCOPE SELECTION GUIDE MIXED SIGNAL AND MIXED DOMAIN OSCILLOSCOPES MDO4000C Additional Resources Channels 4 analog channels; 16 digital channels (with MDO4MSO option); 1 spectrum analyzer input (with SA3 or SA6 option); 1 Arbitrary/Function Generator (with MDO4AFG option) Bandwidth 200 MHz to 1 GHz Spectrum Analyzer Frequency Range Optional: 9 kHz - 3 GHz or 9 kHz - 6 GHz Sample Rate 2.5 GS/s to 5 GS/s (analog); 60.6 ps (16.
OSCILLOSCOPE SELECTION GUIDE ADVANCED SIGNAL ANALYSIS OSCILLOSCOPES MSO/DPO5000B 5 SERIES MSO Channels 4 analog channels; 16 digital channels (MSO5000B) 4, 6, and 8 FlexChannels®; 8 digital channels per FlexChannel (optional); 1 Arbitrary/Function Generator (with 5-AFG option) Bandwidth 350 MHz to 2 GHz 350 MHz to 2 GHz Sample Rate 5 GS/s to 10 GS/s (analog); 60.6 ps (16.5 GS/s) MagniVu™ (digital) 6.25 GS/s (analog); 6.
OSCILLOSCOPE SELECTION GUIDE ADVANCED SIGNAL ANALYSIS OSCILLOSCOPES DPO7000C MSO/DPO70000 Channels 4 analog channels 4 analog channels; 16 digital channels (MSO70000) Bandwidth 500 MHz to 3.5 GHz 4 GHz to 33 GHz Analog Sample Rate 10 GS/s to 40 GS/s 25 GS/s to 100 GS/s (analog); 80 ps (12.5 GS/s) (digital) Max Record Length Up to 500 Mpoints Up to 1Gpoints Trigger Types Pinpoint™ Triggering, Edge, Glitch, Pulse Width, Runt, Time-out, Transition.
OSCILLOSCOPE SELECTION GUIDE ADVANCED SIGNAL ANALYSIS AND SAMPLING OSCILLOSCOPES DPO70000SX DSA8300 Channels 2 or 4 analog channels Six modules support up to 8 single ended or 4 differential channels and/or 2 optical channels Bandwidth 23 GHz to 70 GHz Up to 70+ GHz Electrical bandwidth and 80+ Optical bandwidth modules available with intrinsic jitter as low as <100 fs RMS Sample Rate 50 GS/s to 200 GS/s 300 ks/s Maximum sample rate Max Record Length Up to 1Gpoints 50 to 16,000 per channel na
OSCILLOSCOPE SELECTION GUIDE BASIC OSCILLOSCOPES TBS1000 TBS1000B/ TBS1000B-EDU TBS2000 Channels 4 2 2, 4 Bandwidth 60 MHz to 150 MHz * 30 MHz TBS1032B available in North America and Europe 70 MHz , 100 MHz Sample Rate 1 GS/s 500 MS/s to 2 GS/s 1 GS/s Max Record Length 2.5 k points 2.
OSCILLOSCOPE SELECTION GUIDE BATTERY POWERED OSCILLOSCOPES WITH ISOLATED CHANNELS AND TDS SERIES OSCILLOSCOPES THS3000 TPS2000B TDS2000C TDS3000C Channels 4 (isolated) 2, 4 (isolated) 2, 4 2, 4 Bandwidth 100 MHz to 200 MHz 100 MHz to 200 MHz 50 MHz to 200 MHz 100 MHz to 500 MHz Sample Rate 2.5 GS/s to 5 GS/s 1 GS/s to 2 GS/s 500 MS/s to 2 GS/s 1.25 GS/s to 5 GS/s Max Record Length 10 k points 2.5 k points 2.
OSCILLOSCOPE SELECTION GUIDE OSCILLOSCOPE PROBES AND ACCESSORIES Tektronix probes and accessories are perfectly matched to our industry-leading oscilloscopes. With over 100 choices available, you will find the probe you need.
OSCILLOSCOPE SELECTION GUIDE INTERACTIVE PROBE SELECTOR TOOL Need help finding the right probe for your application? The online Tektronix Probe Selector Tool will guide you through a few easy questions to match your need to the right probe. Visit us anytime, anywhere at: tektronix.com/probes. IsoVu® Isolated Measurement Systems See What’s Been Hidden - Until Now Common mode interference often causes engineers to design, debug, evaluate, and optimize “blind.
OSCILLOSCOPE SELECTION GUIDE SERIAL SUPPORT BY MSO/DPO PRODUCT SERIES AND REQUIRED OPTIONAL SOFTWARE MSO/DPO70000C/DX Series Serial Trigger Compliance Test Decode & Search Serial Trigger Compliance Test I 2C SR-EMBD SR-EMBD - SR-EMBD SR-EMBD - SPI SR-EMBD SR-EMBD - SR-EMBD SR-EMBD - RS-232/UART SR-COMP SR-COMP - SR-COMP SR-COMP - I 2S - - - - - - CAN SR-AUTO SR-AUTO - SR-AUTO SR-AUTO - - - - - - - LIN SR-AUTO SR-AUTO - SR-AUTO SR-AUTO - FlexRay SR-AUTO
OSCILLOSCOPE SELECTION GUIDE SERIAL SUPPORT BY MSO/DPO PRODUCT SERIES AND REQUIRED OPTIONAL SOFTWARE 5 Series MSO Decode & Search Advanced Analysis Datacom Memory Computer / Peripherals Transportation Embedded Serial Standard Serial Trigger MSO/DPO5000B Series Compliance Test Decode & Search Serial Trigger Compliance Test I 2C 5-SREMBD 5-SREMBD - SR-EMBD SR-EMBD - SPI 5-SREMBD 5-SREMBD - SR-EMBD SR-EMBD - RS-232/UART 5-SRCOMP 5-SRCOMP - SR-COMP SR-COMP - IS 5-SRAUDIO 5-S
OSCILLOSCOPE SELECTION GUIDE SERIAL SUPPORT BY MDO PRODUCT SERIES AND REQUIRED OPTIONAL SOFTWARE MDO4000C Series Decode & Search Advanced Analysis Datacom Memory Computer / Peripherals Transportation Embedded Serial Standard Serial Trigger MDO3000 Series Compliance Test Decode & Search Compliance Test Serial Trigger I 2C DPO4EMBD DPO4EMBD - MDO3EMBD MDO3EMBD - SPI DPO4EMBD DPO4EMBD - MDO3EMBD MDO3EMBD - RS-232/UART DPO4COMP DPO4COMP - MDO3COMP MDO3COMP - IS DPO4AUDIO DPO
OSCILLOSCOPE SELECTION GUIDE SERIAL SUPPORT BY MSO/DPO PRODUCT SERIES AND REQUIRED OPTIONAL SOFTWARE MSO / DPO2000B Series Decode & Search Advanced Analysis Datacom Memory Computer / Peripherals Transportation Embedded Serial Standard Compliance Test Serial Trigger I 2C DPO2EMBD DPO2EMBD - SPI DPO2EMBD DPO2EMBD - RS-232/UART DPO2COMP DPO2COMP - IS - - - CAN DPO2AUTO DPO2AUTO - CAN FD - - - LIN DPO2AUTO DPO2AUTO - FlexRay - - - MOST - - - BroadR-Reach - - -
NOTES _____________________________________________________________________________________________________________________________________________________ _____________________________________________________________________________________________________________________________________________________ _____________________________________________________________________________________________________________________________________________________ _______________________________________________________
Contact Information: Australia* 1 800 709 465 Austria 00800 2255 4835 Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Belgium* 00800 2255 4835 Brazil +55 (11) 3759 7627 Canada 1 800 833 9200 Central East Europe / Baltics +41 52 675 3777 Central Europe / Greece +41 52 675 3777 Denmark +45 80 88 1401 Finland +41 52 675 3777 France* 00800 2255 4835 Germany* 00800 2255 4835 Hong Kong 400 820 5835 India 000 800 650 1835 Indonesia 007 803 601 5249 Italy 00800 2255 4835 Japan 81 (3) 6714 3010