GB Via E. Majorana , 49 48022 Lugo (RA) ITALY “CE” DECLARATION OF CONFORMITY in compliance with EC Machine Directive 98/37/EC It is hereby declared that the air conditioner specified below has been designed and built in compliance with essential safety and health requisites as per the European Directive on Machine Safety. This declaration is rendered null and void in the event of incorrect assembly, improper use or modifications made to the machine without our written approval.
GB CONTENTS 1 1.1 1.2 1.3 INTRODUCTION ----------------------------------------------------------------------------------- page 4 Purpose and field of application of the manual ---------------------------------------------- page 4 Key to symbols and definitions ------------------------------------------------------------------ page 4 General information -------------------------------------------------------------------------------- page 4 2 2.1 2.2 2.
GB 1 INTRODUCTION 1.2 Key to symbols and definitions Indicates risk of serious injury or death and that the utmost care must be taken. Always consult this manual carefully before carrying out any work on the conditioner. Situation that might arise during the working life of a product, system or plant which could cause harm, injury, damage to property or environment or result in additional expenses. 1.
GB 2 IDENTIFYING THE AIR CONDITIONER 2.2 ID plate 2.1 Components (fig.
GB 3.2 Weight 2.3 Technical specifications Weight, packaging excluded: SILENT 3800 H 34 kg SILENT 3800 H Power supply 230 V 50 Hz Consumption 2.2 Ampere Peak current 15 A (0.15 sec.) Absorbed power, cooling Absorbed power, heating Cooling capacity 3.3 Handling 510 Watt 510 Watt Packaged air conditioners can be moved using standard means of lifting and transport. The packs have spacers for insertion of transpallet forks.
GB 4.2 Installation Before installing the unit all the following electrical connections on the vehicle must be disconnected. • • • Positive battery lead. Generator (where applicable). Outdoor power socket. Failure to observe the above can lead to power discharges. Before climbing on top of the vehicle check that the roof is designed to be walked on. Check with the vehicle fitter. If it is not, a scaffolding-like framework will be required.
GB Use protective gloves and goggles before using electrical tools or handsaws. Cut the new opening in the roof carefully with a saw: be careful not to cut any electrical wires (fig. 4 ref. 2). 5 4.2.3 Power lead 1 To power the air conditioner it is necessary to lay a 3-pole lead (phase-neutral-earth): each wire must have a minimum cross-section of 2.5 mm2.
GB Working from inside the vehicle, shift the air conditioner until the four fixing threads are aligned with the square 395 x 395 mm opening of the hole on the roof. Line the four external sides of the connecting duct with adhesive insulating tape so that it adheres to the folded fixing edge (fig. 8). Before making any electrical connections always make sure the power is disconnected inside the distribution board and that the wire ends are not live.
GB Fold the two long sides of the connector duct (fig. 12) so that they are horizontally in contact with the horizontal surface of the tunnel. The resulting connection is shown in Fig. 13. Incorrect tightening can damage the support base of the air conditioner, compromise the seal and cause loud noise inside the vehicle when the conditioner is in operation. 4.4 Connecting the power lead Connect the 230 Vac power lead to the one on the just-installed conditioner (fig. 14).
GB 4.5 Installing the diffuser Remove the two adjustable airflow director fins from the diffuser (fig. 15) Then re-insert the two airflow director fins. Note that, on first start-up, fans will start after 3 minutes and the air conditioner after a further 3 minutes. Connect up the panel coupling (Fig. 16) and fasten the diffuser with the 4 self-tapping screws L. 25 mm (fig. 17) 5 INSTRUCTIONS FOR USE 5.
GB • • • • • solenoid valve, which switches gas circulation and so provides a cooling or heating function remote control to program the desired function receiver, situated in the diffuser, which receives the remote control signals electronic board, which receives the signals from the receiver and transforms them into commands for the various electrical components of the air conditioner. • • • • • The SILENT 3800H provides cold air during the summer months and hot air in winter.
GB 5.6 Remote control functions key definitions/ On/Off Press this key to start the air conditioner; press it again to switch it off. 3. Replace the cover. Mode Allows the user to select the working mode: each touch of the key changes the mode. The display shows the following: Display Shows working mode and the fan speed setting (fig. 19) Temperature increase Press this key to increase the temperature setting 5.
GB 5.7 Remote control display (fig. 19) 5.8 AUTOMATIC mode 1) Press the On/Off key. 2) Press the Mode key repeatedly until the display shows the Automatic symbol. 3) Select the desired temperature using the Increase temperature or Decrease temperature keys. 4) Press the Fan speed key repeatedly until the desired fan speed appears. Wait at least 2 minutes between switching off and subsequent switching on so as not to damage the compressor. 5.9 Cooling mode 1) Press the On/Off key.
GB 5.10 working in the conditioning mode; if, instead, the red light (Fig. 20 ref. B) next to the legend “Run” is on the air conditioner is working in the heating mode. Heating mode 1) Press the On/Off key. 2) Press the Mode key repeatedly until the display shows the Heating symbol 3) Select the desired temperature using the Increase temperature or Decrease temperature keys. 4) Press the Fan speed key repeatedly until the desired fan speed appears. The display also shows two numbers (Fig. 20 ref.
GB • • • • • • • 2) Air outflow is insufficient: • check that the directional vents are open enough • check that the diffuser filters are clean enough Installation must be carried out by qualified personnel. Keep children/animals away from the air conditioner unit. Do not insert hands/fingers in ventilation grilles/vents. Do not insert objects into ventilation intakes. If the air conditioner receives any hard knocks have it checked by specialised personnel before using it again.
GB 9 MAINTENANCE 9.1 Routine maintenance All tasks requiring removal of air conditioner covers must – as with installation - be carried out by expert personnel Before carrying out any work on the air conditioner it is essential that you disconnect the 230 V power supply and wait for all its component parts to cool down. • • • • • • Remove the external cover and spray a suitable detergent onto the heat exchangers (evaporator and condenser) and then rinse to remove impurities.
GB GENERAL TERMS OF WARRANTY TELAIR guarantees its products against any construction material and/or manufacturing faults and defects. The right to warranty cover for new products is valid for a period of 24 months from the time of handing over to the end user, or for a maximum of 1000 operating hours, whichever limit is reached first. In all cases the warranty period shall end no later than 26 months (28 months if delivered outside of Europe) after ex factory delivery.
GB 19
GB 20
GB 21
GB Pos/Code/Q.tà 1 / 03476 / n.1 2 / 03493 / n.1 3 / 03482 / n.1 5 / 03696 / n.1 7 / 03443 / n.1 9 / 03942 / n.1 10 / 03378 / n.6 11 / 03500 / n.6 12 / 03698 / n.1 13 / 03478 / n.1 14 / 03940 / n.1 15 / 03503 / n.1 16 / 03915 / n.1 17 / 03700 / n.1 20 / 03701 / n.4 21 / 01842 / n.1 32 / 03497 / n.1 33 / 03499 / n1 34 / 03498 / n.
GB Pos/Code/Q.tà Descrizione/Description Dèsignation/Bezeichnung Denomination/Descripcion Vite di fissaggio M6x100 Vis de fixation M6x100 Bevestigingsschroef M6x100 Fastening screw M6x100 Befestigungsschraube M6x100 Tornillo de fijación M6x100 Elettrovalvola 4 vie DSF Électrovanne 4 voies DSF 4 - weg elektromagneetklep 4/230 V 4/230 V DSF - 4/230 V 45 / 03337 / n.