2.3 Technical specifications
SILENT 3800 H
Power supply 230 V 50 Hz
Consumption 2.2 Ampere
Peak current 15 A (0.15 sec.)
Absorbed power, cooling 510 Watt
Absorbed power, heating 510 Watt
Cooling capacity 3800 Btu/h
Heating capacity 3800 Btu/h
Type and quantity of coolant gas R 134a … 500 g
N° of fan speeds 3
Air flow rate 270 m3/h
Waterproof rating IP X4
Generator required 2200 W
Diffuser dimensions (H x L x W) 6.3x52.3x51 cm
Monobloc dimensions (H x L x W) 21.5x98x65 cm
Weight 34 Kg
Some of the technical characteristics
in this table may vary.
Only the data shown on the actual
conditioner identification plate is valid.
3 TRANSPORT, HANDLING,
STORAGE
3.1 Storage
During transport the air conditioner is
protected by its cardboard packaging.
The conditioner must be stored indoors in a
horizontal position in a dry, ventilated area.
The type of packaging allows up to 5 (five)
conditioners to be stacked on top of each
other.
Do not turn the package
upside-down. The right way up is
indicated by the symbol on the packaging
( ↑↑).
Stacking more than five
packaged air conditioners can damage the
conditioners themselves and put
personnel at risk of injury.
3.2 Weight
Weight, packaging excluded:
SILENT 3800 H 34 kg
3.3 Handling
Packaged air conditioners can be moved
using standard means of lifting and transport.
The packs have spacers for insertion of
transpallet forks.
Always observe safety
and accident prevention
regulations when lifting and transporting.
Use only lifting and transport gear of a
load bearing capacity greater than the
weight to be lifted.
4 INSTALLATION
4.1 Preliminary information
Before installing the
conditioner you must read these
instructions thoroughly to prevent errors.
Incorrect installation can
irreparably damage the air conditioner
and compromise user safety.
European Machine Directive 89/392/EEC
states that the manufacturer cannot be held
liable for poor air conditioner performance
and/or safety should the air conditioner fail to
be installed in observance of the information
provided in this manual. Moreover, the
manufacturer cannot be held liable for any
resulting injury or damage.
Installation must only be
carried out by qualified, specially trained
personnel.