User's Manual

5
Current consumption
RECEIVER MODEL SUPPLY VOLTAGE MAX. CURRENT CONSUMPTION
R8-1 12-24 V DC <200 mA.
Technical data
FUNCTIONAL RELAYS: 5 potential free* functional relays
NO/NC 8A ACI
NUMBER OF CHANNELS: 16
SIZE: 120 x 116 x 50 mm./
4.7” x 4.6” x 2”
WEIGHT: 400 grams/ 14 oz.
IP CLASS: IP66
FREQUENCY: 2405-2480 MHz.
* Potential free means that you need to supply voltage to get power out of a relay (e.g. via a
connection comb).
SYSTEM APPLICATION AREA
The Panther system is a simplex radio communication system that is
preferentially aimed towards professional industry, e.g. radio controlling of
winches and mobile applications. The functionality of the Panther systems
is as varied and versatile as are the needs of our customers.