Installation Instructions

1. Terminal block for power supply
(PWR)
1
, stop relays (SR) and
function relays (R)
2. Connector for input power
2
3. Stop relays SR12
4. Connector for 48–230VAC
5. Connector for 1224VAC/DC
6. Connector for 1224VDC
3
7. Function relays 110 (NO)
8. Connector for expansion board
4
9. Connector for DO 12
10. Connector for expansion board
TR507
5
11. Connector for expansion board
6
12. Connector for expansion board
7
13. Power LED (yellow)
14. TRABUS contact
15. Radio module (TR362)
16. Function LEDs
(1 = red, 2 = yellow, 3 = green, 4 =
orange)
17. Connector for expansion board
8
18. PLd status LED (red)
19. Function button (cancel)
20. Select button (OK)
21. Status LEDs for digital outputs 12
(red)
22. LED indicators for stop relays
SR12
23. Relay LEDs 110 (red)
6.1.1CONNECTOR FOR DIGITAL OUTPUTS ON THE BASEBOARD
1. +5V
2. Digital output 1
9
3. Digital output 2
4. GND
1
By design, input power (PWR) is also connected to connector J21.
2
To be connected to either J43, J44 or J45, depending on the voltage to achieve.
3
Input to be used when the receiver needs to be able to go low in voltage.
4
RS485
5
CAN/J1939
6
Digital inputs (not in use for the moment).
7
Big relay board (not in use for the moment).
8
Relay/DO/+12V
9
Open drain, max. voltage 30V, max. current 100 mA
26 IM-PN-RX107-CERT-01pre4