Datasheet

Subject to alterations and errors
www.tele-power-net.com
Accessories - Timers
Remote potentiometer - RONDO R2
Technical data
1. Functions
F Remote potentiometer
2. Mechanical design
Self-extinguishing plastic housing, IP rating IP64 (frontside)
Mounted in front panel aperture clear diameter 22.5mm by
means of retaining clip (included) according to DIN 43700
Mounting position: any
Shockproof terminal connection according to VBG 4
Initial torque: max. 1Nm
Terminal capacity:
1 x 0.5 to 1,0mm² with/without multicore cable end
3. Output circuit
Maximum adjustment value:
1M (R2 1M 0.1) Scale 0.1 to1
1M (R2 1M 0.3) Scale 0.3 to3
Connections:
1 First
2 Wiper
3 Finish
Insulation voltage: 250V AC (according to IEC 664-1)
Surge voltage: 4kV, overvoltage category III
(according to IEC 664-1)
4. Accuracy
Base accuracy: ±10% (of maximum scale value)
Repetition accuracy: 0,01%
5. Ambient conditions
Ambient temperature: -25 to+55°C (according to IEC 68-1)
Storage temperature: -25 to+65°C
Transport temperature: -25 to+65°C
Relative humidity: 15% to 85%
(according to IEC 721-3-3 class 3K3)
Pollution degree: 3 (according to IEC 664-1)
DimensionsFunctions
Remote potentiometer for front panel mounting. With the remote
potentiometer time values can be adjusted from a distance.
Connections
1
2
3
First
Wiper
Finish