5. Programming the ManDown Sensor
To program a ManDown Sensor within a Carephone social alarm system (e.g. Carephone 10
(AP1337), Carephone 12 (Caveo) or within a NurseCall system, follow the procedure de-
scribed for the system you are using. As the ManDown Sensor can
be considered as a stan-
dard transmitter, the system will recognize it during the programming step. Please refer to
the manual of the corresponding social alarm system.
6. Maintenance
6.1. Safety instructions
Caution!
There is a danger of explosion if the replacement of the battery is not
performed correctly!
Replace the battery only by an identical or equivalent type.
Dispose of the used batteries at an appropriate recycling facility.
Although battery replacement may be done by non-specialized person-
nel, the manufacturer recommends that it should be performed by your
local dealer.
Caution!
The ManDown Sensor contains highly sensitive electronic components.
It should always be opened in an ESD (E
lectro Static Discharge) pro-
tected environment, with respect to the following precautions:
Discharge yourself from electrostatic loads by touching a grounded
conductive surface before opening the unit.
Avoid touching conductive parts and metallic surfaces if not abso-
lutely necessary.
6.2. Storage
Short term storage (less than two weeks)
Deactivate the sensor.
Long term storage (more than two weeks)
Remove the battery and store the ManDown Sensor protected from direct sunlight, moisture
and dust.