7.1.12 IRecOptions::Reset
HRESULT Reset ( );
Resets recording options to its initial state.
Parameters
Return values
Remarks
For default values of recording options, see the remarks.
Example
WSH:
CurrentDir = Left(WScript.ScriptFullName, InstrRev(WScript.ScriptFullName, "\"))
Set Analyzer = WScript.CreateObject("CATC.USBTracer")
Set RecOptions = Analyzer.GetRecordingOptions
RecOptions.SetRecMode 2 ' Event trigger
RecOptions.SetBufferSize 1024*1024 ' 1 MB
RecOptions.SetPostTriggerPercentage 60 ' 60%
. . .
RecOptions.Reset
C++: