3.1.6 ITrace::ReportFileInfo
HRESULT ReportFileInfo (
[in] BSTR file_name );
Saves trace information into the specified text file.
Parameters
file_name String with full pathname to file where trace information report is created
Return values
ANALYZERCOMERROR_UNABLESAVE Unable to create trace information report.
Remarks
Creates trace information file if necessary. Stores trace information in specified file. Here is an
example of data stored using this method call:
File name : data.usb
Comment :
Recorded on Channel number : 0
Number of packets : 22514
Trigger packet number : 0
Recorded with application version 1.70 ( Build 102 )
Analyzer Serial Number 00213
Traffic Generation enabled
Firmware version 1.06 ( ROM 1.02 )
BusEngine version 1.90
BusEngine type 1
UPAS Slot 1 Part# US005MA PlugIn ID: 0x01 Version 0x4
UPAS Slot 2 Part# US005MG PlugIn ID: 0x04 Version 0x4
Number of markers : 1
Recording Options:
Options Name: Default
Recording Mode: Snapshot
Buffer Size: 2.000 MB
Post-trigger position: 50%
Base filename & path: E:\AnalyzerSw\Chief20\Debug_UPA\data.usb
Save External Signals No
Auto-Merge No
Truncate Data No
Devices setup for On-the-Go operation
2 DRD's: A device is named Camera, B device is named Printer
Assumes first trace data is captured when A-Device is Host
Channel 0 Trace Speed Recording Mode: Full Speed Only
Channel 0 Recording Events:
Channel 1 Trace Speed Recording Mode: Full Speed Only
Channel 1 Recording Events:
Channel 0 is Full Speed.
Recorded on product: USBTracer
License information for the USBTracer unit, Serial Number 00213, used to record this trace file
:
Software maintenance hasn't been enabled.