DEBUG IN HIGH DEFINITION 4000 6000 200 MHz – 1 GHz Oscilloscopes 8000 Lowest Noise and Powerful Toolbox HD4096 Technology Superior User Experience Powerful, Deep Toolbox Exceptional Serial Data Tools teledynelecroy.com/hdo The HDO4000A with HD4096 Technology provides exceptional signal fidelity with 12-bit resolution and a superior oscilloscope experience to deliver faster time to insight.
DEBUG IN HIGH DEFINITION High Definition Oscilloscopes with HD Technology have a variety of benefits that allow the user to debug in high definition. Waveforms displayed by High Definition Oscilloscopes are cleaner and crisper. More signal details can be seen and measured; these measurements are made with unmatched precision resulting in better test results and shorter debug time. Clean, Crisp Waveforms Experience HD4096 accuracy, detail, and precision and never use an 8-bit oscilloscope again.
HDO4000A HDO6000A HDO8000A HDO9000 HD4096 HD4096 HD4096 HD1024 12 bits 12 bits 12 bits 10 bits Bandwidth 200 MHz - 1 GHz 350 MHz - 1 GHz 350 MHz - 1 GHz 1 GHz - 4 GHz Input Channels 4 4 8 4 Sample Rate 10 GS/s 10 GS/s 10 GS/s 40 GS/s Standard Toolbox Basic Advanced Advanced Advanced Serial Data Tools TD TDME TDME TDME, SDAII, QPHY User Experience MAUI with OneTouch MAUI with OneTouch MAUI with OneTouch MAUI with OneTouch HD Technology HD1024 technology provides 10
DEBUG IN HIGH DEFINITION Lowest Noise and Powerful Toolbox HD4096 technology enables 12 bits of vertical resolution with 1 GHz bandwidth HD4096 • Clean, Crisp Waveforms High Definition Technology Deep Toolbox 4 4000 6000 8000 • More Signal Details • Unmatched Measurement Precision OBSESSED WITH TOOLS HDO4000A has the greatest breadth and depth of tools, ensuring quick resolution of the most complicated debug tasks.
1 HD4096 Technology 2 Superior User Experience 3 Powerful, Deep Toolbox 4 Exceptional Serial Data Tools The HDO4000A with HD4096 Technology provides exceptional signal fidelity with 12-bit resolution and a superior oscilloscope experience to deliver faster time to insight. Insight alone is not enough. Markets and technologies Faster Time to Insight change too rapidly. The timing of critical design decisions is significant. Faster Time to Insight is what matters.
MAUI® – SUPERIOR USER EXPERIENCE MAUI – Most Advanced User Interface was developed to put all the power and capabilities of the modern oscilloscope right at your fingertips. Designed for touch; all important oscilloscope controls are accessed through the intuitive touch screen. Built for simplicity; time saving shortcuts and intuitive dialogs simplify setup. Made to solve; a deep set of debug and analysis tools helps identify problems and find solutions quickly.
POWERFUL, DEEP TOOLBOX Our Heritage Our Obsession Our Invitation Teledyne LeCroy’s 50+ year heritage Our developers are true to our heritage Our Periodic Table of Oscilloscope has its origins in the high-speed – they are more obsessed with making Tools provides a framework to collection of data in the field of high- better and smarter tools than anybody understand the toolsets that Teledyne energy physics, and the processing else.
HD4096 TECHNOLOGY – 16X CLOSER TO PERFECT Teledyne LeCroy HDO high definition oscilloscopes use unique HD4096 technology to provide superior and uncompromised measurement performance: – 12-bit ADCs with high sample rates – High signal-to-noise amplifiers (55 dB) – Low noise system architecture (to 1 GHz) Oscilloscopes with HD4096 technology have higher resolution than conventional 8-bit oscilloscopes (4096 vs. 256 vertical levels) and low noise for uncompromised measurement performance.
EXPERIENCE THE DIFFERENCE Experience HD4096 accuracy, detail, and precision and never use an 8-bit oscilloscope again. Whether the application is general-purpose design and debug, high-precision analog, power electronics, automotive electronics, mechatronics, or other specialized applications, the HD4096 technology provides unsurpassed confidence and measurement capabilities.
HDO4000A AT A GLANCE HDO4000A oscilloscopes have 4 analog input channels, 12-bit resolution using Teledyne LeCroy’s HD4096 high definition technology, up to 1 GHz of bandwidth and a compact form factor with a large 12.1” multi-touch display. They are ideal for debug and troubleshooting of power electronics designs, digital power management or power integrity analysis, automotive electronics systems, and deeply embedded or mechatronic designs.
1 Only 13 cm (5”) Deep – The most space-efficient oscilloscope for your bench from 200 MHz to 1 GHz 1 2 12.1” Widescreen (16 x 9) high resolution WXGA color multi-touch screen display.
POWERFUL MIXED SIGNAL CAPABILITIES The HDO4000A High Definition Oscilloscopes offer powerful mixed signal solutions that combine high definition analog channels with the flexibility of digital inputs. The HDO4000A-MS options provide an integrated 16 digital channels and a 1.25 GS/s sampling rate to create an all-in-one debug machine.
STANDARD TOOLS FOR ADVANCED ANALYSIS WaveScan Advanced Search WaveScan provides powerful isolation capabilities that hardware triggers can’t provide. WaveScan allows searching analog, digital or parallel bus signal in a single acquisition using more than 20 different criteria. Or, set up a scan condition and scan for an event over hours or even days.
2 TD EXCEPTIONAL SERIAL DATA TOOLS A B The HDO4000A features the widest range A and most complete serial A B A data B debug toolsets.
DOCUMENTATION AND SEQUENCE MODE LabNotebook Documentation Tool LabNotebook is a standard feature of HDO4000A and is the ideal documentation tool. LabNotebook automatically saves all displayed waveforms, oscilloscope setup file, and a screen image with a single button press, eliminating the need to navigate multiple menus to save all these files independently. Report files can be annotated and shared with colleagues to fully document all results.
SPECTRUM ANALYZER OPTION Key Features Spectrum analyzer style controls for the oscilloscope Dual Spectrum Capability Select from six vertical scales (in dB, V, or A) utomatic frequency peak A identifications Display up to 20 markers, with interactive table readout of frequencies and levels Easily make measurements with reference and delta markers Automatically identify and mark fundamental frequency and harmonics Spectrogram shows how spectra changes over time in 2D or 3D views Use two independent input
POWER ANALYSIS OPTION Key Features Automated measurement zone identification with color-coded overlays Control loop and time domain response analysis Line power and harmonics tests to IEC 61000-3-2 Total harmonic distortion table shows frequency contribution -H Curve shows magnetic device B saturation Power Analyzer Automates Switching Device Loss Measurements Quickly measure and analyze the operating characteristics of power conversion devices and circuits with the Power Analyzer option.
PROBES Teledyne LeCroy offers an extensive range of probes to meet virtually every probing need. ZS Series High Impedance Active Probes ZS1000, ZS1000-QUADPAK ZS1500, ZS1500-QUADPAK Differential Probes (200 MHz – 1.5 GHz) ZD1500, ZD1000, ZD500, ZD200 AP033 Active Voltage/Power Rail Probe RP4030 High input impedance (1 MΩ), low 0.9 pF input capacitance and an extensive set of probe tips and ground accessories make these low-cost single-ended probes ideal for a wide range of applications.
SPECIFICATIONS Vertical - Analog Channels Bandwidth @ 50 Ω (-3 dB) Rise Time (10–90%, 50 Ω) Input Channels Vertical Resolution Effective Number of Bits (ENOB) Vertical Noise Floor 1 mV/div 2 mV/div 5 mV/div 10 mV/div 20 mV/div 50 mV/div 100 mVdiv 200 mV/div 500 mV/div 1 V/div Sensitivity DC Vertical Gain Accuracy (Gain Component of DC Accuracy) Channel-Channel Isolation Offset Range DC Vertical Offset Accuracy Maximum Input Voltage Input Coupling Input Impedance Bandwidth Limiters Horizontal - Analog Cha
SPECIFICATIONS HDO4024A HDO4024A-MS HDO4034A HDO4034A-MS HDO4054A HDO4054A-MS HDO4104A HDO4104A-MS Vertical, Horizontal, Acquisition - Digital Channels (with HDO4000A-MS only) Input Channels Threshold Groupings Threshold Selections Maximum Input Voltage Threshold Accuracy Input Dynamic Range Minimum Input Voltage Swing Input Impedance (Flying Leads) Maximum Input Frequency Sample Rate Record Length Minimum Detectable Pulse Width Channel-to-Channel Skew User Defined Threshold Range User Defined Hysteres
SPECIFICATIONS Measurement Tools Measurement Functionality Measurement Parameters Horizontal + Jitter Measurement Parameters - Vertical Measurement Parameters - Pulse HDO4024A HDO4024A-MS HDO4034A HDO4034A-MS HDO4054A HDO4054A-MS HDO4104A HDO4104A-MS Display up to 8 measurement parameters together with statistics, including mean, minimum, maximum, standard deviation, and total number. Each occurrence of each parameter is measured and added to the statistics table. .
SPECIFICATIONS Processor/CPU Type Processor Memory Operating System Oscilloscope Operating Software Connectivity Ethernet Port USB Host Ports USB Device Port GPIB Port (Optional) External Monitor Port Remote Control Probes Standard Probes Probing System Power Requirements Voltage Power Consumption (Nominal) Max Power Consumption Environmental Temperature Humidity Altitude Random Vibration Functional Shock Physical Dimensions (HWD) Weight Certifications CE Certification UL and cUL Listing War
ORDERING INFORMATION Product Description Product Code HDO4000A Oscilloscopes 200 MHz, 10 GS/s, 4 Ch, 12.5 Mpts/Ch 12-bit HD Oscilloscope with 12.1" WXGA Touch Display 350 MHz, 10 GS/s, 4 Ch, 12.5 Mpts/Ch 12-bit HD Oscilloscope with 12.1" WXGA Touch Display 500 MHz, 10 GS/s, 4 Ch, 12.5 Mpts/Ch 12-bit HD Oscilloscope with 12.1" WXGA Touch Display 1 GHz, 10 GS/s, 4 Ch, 12.5 Mpts/Ch 12-bit HD Oscilloscope with 12.
ORDERING INFORMATION Product Description Probes and Amplifiers Product Code 250 MHz Passive Probe for HDO4000A, 10:1, 10 MΩ PP017 500 MHz Passive Probe 10:1, 10 MΩ PP018 500 MHz Passive Probe, 5mm, 10:1, 10 MΩ PP026 Power/Voltage Rail Probe. 4 GHz bandwidth, 1.