Operators Manual Owner manual

Operator's Manual
Dialogs
Dialogs appear at the bottom of the display for entering setup data. The top dialog will be the main entry
point for the selected setup option. For convenience, related dialogs appear as a series of tabs behind the
main dialog. Touch the tab to open the dialog.
Dialogs may also display right-hand dialogs (sub-tabs) or pop-up dialogs. These often change depending
on the other selections made on the left-hand dialog.
Many dialog settings can be made using either the touch screen or the Front Panel buttons.
Shortcut Toolbar
Several setup dialogs contain a row of buttons at the bottom of the dialog. These provide a shortcut to
common functions without having to leave the underlying set up dialog.
Measure - Opens the Measure pop-up to set measurement parameters on the active trace.
Zoom - Creates a zoom trace of the active trace.
Math - Opens the Math pop-up to apply math functions to the active trace and create a new math trace.
Decode - Opens the main Serial Decode dialog where serial data decoders can be configured and applied.
Store - Loads the active trace into the corresponding memory location (C1, F1 and Z1 to M1; C2, F2 and
Z2 to M2, etc.).
Find Scale - Automatically performs a vertical scaling that fits the waveform into the grid.
Next Grid - Automatically moves the active trace to the next grid. If you have only one grid displayed, a
new grid will be created automatically, and the trace moved.
Label - Opens the Label pop-up to annotate the active trace.
The following buttons appearing at the bottom of the Measure (Px) dialogs. They allow you to create a
Math function to draw the corresponding type of plot (Histogram, Trend, or Track) while remaining on the
Measure setup dialog.
Control Application Window
The oscilloscope applications runs on a Windows Embedded Standard 7P Operating System and functions
exactly as do other Windows applications. The application software loads automatically when you turn on
the oscilloscope using the Power button.
To minimize the application window and show the Windows desktop, touch the minimize button or choose
File > Minimize. To restore the window after minimizing, touch the oscilloscope display icon in the lower
right corner of the desktop.
To exit the application window, choose File > Exit. When you exit the application, the oscilloscope
operating system continues to run. To reload the application after exiting, touch the Start DSO desktop
shortcut.