Operators Manual Owner manual

HDO6000 High Definition Oscilloscope
Digital Group Set Up
1. From the menu bar, choose Vertical > Digital <#> Setup, or press the Front Panel Dig button and select
the desired Digital<#> tab.
2. On the Digital<#> set up dialog, check the boxes for lines D0 through D15 that comprise the group.
Touch the Display D0-D7 and Display D8-D15 buttons to quickly turn on the entire digital bank, or
touch the Right and Left Arrow buttons to switch between each digital bank as you make line
selections.
NOTE: Each group can consist of anywhere from 1 to 16 of the leads that are (or will be) connected to
signal, from either digital bank regardless of the Logic set on the bank. It does not matter if the some
or all of the lines have been included in other groups.
3. When all group members are selected, optionally rename them.
4. Go on to set up the digital display for the group. Check Group to enable the display.
5. When you're finished on the Digital<#> dialog, touch the Logic Setup tab and choose the Logic Family
that applies to each digital bank, or set custom Threshhold and Hysteresis values.
Digital Display Set Up
You can choose the type and position of the digital traces that appear on screen for each digital group.
1. Set up the digital group.
2. Touch Display Mode and choose from:
l Lines - the default display, which shows a time-correlated trace indicating high, low, and tran-
sitioning points (relative to the Threshold) for every digital line in the group. The size and place-
ment of the lines depend on the number of lines, the Vertical Position and Group Height
settings.
l Bus - which collapses the lines in a group into their Hex values. It appears immediately below
all the Line traces when both are selected.
l Lines & Bus - which displays both line and bus traces at once.
32