© 2013 Teledyne LeCroy, Inc. All rights reserved. Unauthorized duplication of Teledyne LeCroy documentation materials other than for internal sales and distribution purposes is strictly prohibited. However, clients are encouraged to distribute and duplicate Teledyne LeCroy documentation for their own internal educational purposes. WaveSurfer, WaveRunner, and Teledyne LeCroy are registered trademarks of Teledyne LeCroy, Inc. Windows is a registered trademark of Microsoft Corporation.
PP011 Passive Probe Safety Instructions This section contains instructions that must be observed to keep this oscilloscope accessory operating in a correct and safe condition. You are required to follow generally accepted safety procedures in addition to the precautions specified in this section. The overall safety of any system incorporating this accessory is the responsibility of the assembler of the system.
Operator’s Manual Do not overload. To avoid electric shock or fire, do not apply any potential to the probe leads that exceeds the maximum rating of the probe. Comply with voltage derating curve. When measuring higher frequency signals, comply with the Voltage vs. Frequency Derating Curve. Observe all terminal ratings. To avoid electric shock or fire, observe all markings on the oscilloscope before connecting. Consult the respective oscilloscope product manual for further ratings information.
PP011 Passive Probe Introduction The PP011 is a miniature high impedance passive probe. Its high input resistance and low capacitance make it ideal for general purpose probing of signals with frequency content from DC through several hundred MHz. The PP011 has a large selection of connection accessories, supplied standard with the probe and available from Teledyne LeCroy as optional accessories. The PP011 is designed for use with 600 MHz and higher Teledyne LeCroy WaveSurfer oscilloscopes.
Operator’s Manual Specifications Electrical Characteristics Attenuation 10 1% Input Resistance 10 M 1% Input Capacitance 9.5 pF Input Impedance (see plot on next page) Compensation Range 10 – 20 pF Bandwidth 500 MHz (-3 dB) Electrical Ratings* Maximum Input Voltage Measurement category I: 400 V rms, 1250 V transient overvoltage (see voltage derating curve below) Measurement category II: 300 V rms CAT II Pollution Degree 2 * See Certifications for an explanation of ratings.
PP011 Passive Probe Max.
Operator’s Manual Connectivity Accessories Teledyne LeCroy provides 24 individual accessories for the PP011 probe, which enable reliable connections to any physical requirement. In addition to those provided with the standard probe, several optional varieties are available either individually, or grouped in sets related to specific application needs. The PK005A series of connectivity accessories are compatible with any Teledyne LeCroy 5 mm PP011 series probe.
PP011 Passive Probe Optional Accessories TIPS AND SPRINGS PK1-5MM-109 Spring Tip, 0.8 mm PK1-5MM-124 Spring Tip, 0.38 mm PK1-5MM-108 IC Cap, 2.
Operator’s Manual GROUND LEADS PK1-5MM-119 Ground Lead with mini clip PK1-5MM-120 Ground Lead with 8 mm socket PK1-5MM-122 Ground lead with 4 mm plug PK1-5MM-121 Ground Lead with 2 mm plug PK1-5MM-123* High Frequency Compensated Ground Lead *The PK1-5MM-123 High Frequency compensated ground lead allows operation with long ground lead with minimum signal distortion.
PP011 Passive Probe Use and Maintenance This probe is a high quality, precision instrument. To maintain accuracy and signal fidelity, mechanical shock should be avoided, as well as damage to the cable through excessive bending. To achieve the small 2.5 mm tip size, the input tip diameter is narrower than those in larger probes. Avoid placing excessive force sideways on the tip. Should the tip become damaged, it may be replaced by the user using the procedure listed on the last page.
Operator’s Manual Probe Compensation Proper compensation of the probe is required to assure good amplitude accuracy in the dynamic portions of the waveform being measured. LF compensation matches the probe to differences in oscilloscope input capacitance. The LF compensation should always be checked and adjusted as needed when first connecting a passive probe to the oscilloscope input. HF compensation matches time constants within the probe to compensate for normal component tolerances.
PP011 Passive Probe Tip Selection and Exchange The PP011 probe is supplied with two tip styles. The spring tip, which is installed when the probe is shipped, combines a sharp point with on-axis compliance. This provides reliable connection under a wide range of physical interconnect situtations. A rigid tip is also supplied. While lacking the on-axis compliance feature of the spring tip, the rigid tip has a larger diameter and is more robust when exposed to physical stress at the tip.
Operator’s Manual Certifications This section certifies the probe’ Safety and Environmental compliance. EC Declaration of Conformity - Safety The probe meets intent of EC Directive 2006/95/EC for Product Safety.
PP011 Passive Probe Contact Teledyne LeCroy Teledyne LeCroy Service Centers United States and Canada World Wide Corporate Office Teledyne LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499, USA Ph: 800-553-2769 / 845-425-2000 FAX: 845-578-5985 teledynelecroy.com Support: contact.corp@teledynelecroy.com Sales: customersupport@teledynelecroy.
Operator’s Manual 922224-00 Rev A 15
PP011 Passive Probe 16 922224-00 Rev A