700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 425-2000, Fax: (845) 578 5985 teledynelecroy.com PP021 Passive Probe Instruction Manual © 2015 Teledyne LeCroy, Inc. All rights reserved. Unauthorized duplication of Teledyne LeCroy documentation materials other than for internal sales and distribution purposes is strictly prohibited. However, clients are encouraged to duplicate and distribute Teledyne LeCroy documentation for internal educational purposes.
Operator’s Manual Terms and Symbols The following symbols appear on the product or in its documentation: DANGER High Voltage WARNING Refer to Manual. Condition or practice could result in injury or loss of life.
PP021 Passive Probe Specifications Model PP021 Input Imped. Attn. 10x B/W Rise Time Length Compensation Range R (MΩ) C (pF) (MHz) (ps) (m) (pF) 10 11 500 700 1.3 14 - 25 Attenuation Ratio ..................... 10:1 ± 1% 1 Max. Input Voltage................... Measurement Category I : 500 Vrms 1500 V transient overvoltage (see voltage derating curve on p. 3) 2 Measurement Category II : 400 Vrms Pollution Degree ...................... Pollution Degree 2 3 Operating Temperature .......
Operator’s Manual PP021 Input Impedance Profile Voltage vs.
PP021 Passive Probe EC Declaration of Conformity The probe is marked with this symbol to show compliance was demonstrated to the specifications listed in the Official Journal of the European Communities: Low Voltage Directive 2006/95/EC: EN 61010-031/A1:2008 Safety requirements for electrical equipment for measurement, control and laboratory use – Part 031: Safety requirements for handheld probe assemblies for electrical measurement and test.
Operator’s Manual Do not overload. Do not apply any potential to the probe leads that exceeds the maximum rating of the probe. Always comply with the Voltage vs. Frequency Derating Curve. Observe all terminal ratings. Observe all markings on the oscilloscope before connecting. Consult the oscilloscope product manual for further ratings information. Do not remove probe casing. Touching exposed connections may result in electric shock. Use indoors only within operational environment listed.
PP021 Passive Probe Probe Compensation Proper compensation of the probe is required to assure amplitude accuracy of the waveform being measured by matching the probe to the oscilloscope’s input capacitance. Compensation should be adjusted whenever the probe is connected to or transferred between oscilloscopes. Low Frequency 1. Apply a 1 kHz square wave to the probe or connect to the oscilloscope’s calibrator output. 2.
Operator’s Manual Over-compensated, correct, and under-compensated waveforms Probe Accessories Probe Tips Both the rigid probe tip and the spring tip can be screwed on to the probe body by hand. Be sure not to overtighten the tips to avoid damaging the threads. Ground Accessories The ground lead and the short collar are attached to the probe at the time of shipping. To replace the ground lead with the swivel lead adapter, unscrew the short collar from the probe and remove the ground lead.
PP021 Passive Probe Replaceable Parts Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Part Number PK5-2.5MM-101 PK5-2.5MM-102 PK5-2.5MM-103 PK5-2.5MM-104 PK5-PK6-001 PK5-2.5MM-105 PK5-2.5MM-106 PK5-2.5MM-107 PK5-2.5MM-108 PK5-2.5MM-109 PK5-2.5MM-110 PK5-2.5MM-111 PK5-2.5MM-112 PK5-2.5MM-113 PK5-2.
Operator’s Manual Warranty NOTE: THE WARRANTY BELOW REPLACES ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS, OR ADEQUACY FOR ANY PARTICULAR PURPOSE OR USE. TELEDYNE LECROY SHALL NOT BE LIABLE FOR ANY SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER IN CONTRACT OR OTHERWISE. THE CUSTOMER IS RESPONSIBLE FOR THE TRANSPORTATION AND INSURANCE CHARGES FOR THE RETURN OF PRODUCTS TO THE SERVICE FACILITY.
PP021 Passive Probe Teledyne LeCroy Service Centers World Wide Corporate Office Teledyne LeCroy 700 Chestnut Ridge Road Chestnut Ridge, NY, 10977, USA teledynelecroy.com Sales and Service: Ph: 800-553-2769 / 845-425-2000 FAX: 845-578-5985 contact.corp@teledynelecroy.com Support: Ph: 800-553-2769 support@teledynelecroy.com US Protocol Solutions Group Teledyne LeCroy 3385 Scott Boulevard Santa Clara, CA, 95054, USA teledynelecroy.
Operator’s Manual European Headquarters Teledyne LeCroy SA 4, Rue Moïse Marcinhes Case postale 3411217 Meyrin 1 Geneva, Switzerland teledynelecroy.com/Europe Ph: + 41 22 719 2111 FAX: + 41 22 719 2230 contact.sa@teledynelecroy.com China LeCroy Corporation Beijing Rm. 2001, Unit A, Horizon Plaza No. 6, Zhichun Road, Haidian Dist. Beijing 100088, China www.lecroy.com.cn Sales: Ph: 86-10-82800318/0319/0320 FAX:86-10-82800316 Marketing.China@teledynelecroy.com Service: Rm. 2002 Ph: 86-10-82800245 Service.
PP021 Passive Probe Korea Teledyne LeCroy Korea 10th fl. 333 Yeongdong-daero Gangnam-gu Seoul 135-280, Korea teledynelecroy.com/korea Ph: ++ 82 2 3452 0400 FAX: ++ 82 2 3452 0490 Japan Teledyne LeCroy Japan 3F, Houbunshafuchu Bldg. 3-11-5, Midori-cho, Fuchu-Shi Tokyo 183-0006, Japan teledynelecroy.
926213-00 November, 2015