These are the standard 10GBase-KR compliance tests.
Jitter: Tj, Rj, Dj, DCD & BitRate
This test measures all timing parameters that can be measured on a PRBS or scrambled data
signal. The measurements are directly produced by SDAII or SDAIII.
Voltage Measurements Single Ended on 0101
This test measures MaxDiffPPOutVoltage, MaxCommonMode and MinCommonMode, and
DutyCycle. MaxCommonMode is 1.9V. The MinDiffCommonMode limit is -0.04 V, even though
the spec is 0, so that readings within scope tolerance for DC accuracy will pass.
Voltage Measurements Differential on 0101
This test measures MaxDiffPPOutVoltage and Duty Cycle. It is not possible to measure
common mode voltage through a differential probe; the probe does its best to suppress
common mode.
Transition Time Test
This test measures Rise 20%-80% and Fall 80%-20%. Results must be between 24 and 47ps.
TX Output Waveform Tests
See IEEE Std 802.3 sections:
72.7.1.10 Transmitter output waveform
72.7.1.11 Transmitter output waveform requirements (Table 72-8 and requirements that
follow it, particularly)
TX EQ part 1: C(0) min, C(1) and C(-1) disabled
TX EQ part 2: C(0) max, C(1) and C(-1) disabled
TX EQ part 3: C(0) and C(1) min, C(-1) disabled
TX EQ part 4: C(0) and C(-1) min, C(1) disabled
In each of these sections several “level matching” requirements are checked, and the invariant
requirements on “delta V2” and “delta V5” are checked.