Oscilloscope Probes and Probe Accessories
PROBE SELECTION GUIDE Learn More: teledynelecroy.com/probes Teledyne LeCroy has a wide variety of world class probes and amplifiers to compliment its product line. From the ZS high impedance active probes to the DH Series Differential High-bandwidth Probes which offers bandwidths up to 30 GHz, Teledyne LeCroy probes and probe accessories provide optimum mechanical connections for signal measurement.
WaveSurfer 4000HD High Definition Oscilloscopes HDO6000A High Definition Oscilloscopes WaveRunner 9000 Oscilloscopes WaveRunner 8000HD High Definition Oscilloscopes/ MDA8000HD Motor Drive Analysers WavePro HD High Definition Oscilloscopes WaveMaster/SDA/DDA/8 Zi-B Oscilloscopes ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ HVD3206A-6M ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ HVD3605A ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
ACTIVE VOLTAGE RAIL PROBE 4
ACTIVE VOLTAGE RAIL PROBE The RP4030 is designed specifically to probe a 50Ω DC power/voltage rail. The probe has large built-in offset, low attenuation (noise), and high DC input impedance. Built-in offset and low attenuation permit the power/voltage rail to be offset in the oscilloscope by its mean DC voltage with high oscilloscope gain (sensitivity) to achieve a noise-free view of small signal variations.
ACTIVE VOLTAGE RAIL PROBE Teledyne LeCroy Active Voltage Rail Probe Model Number: RP4030 Key Features 4 GHz Bandwidth ±30V Offset Capability ±800mV Dynamic Range 50 kΩ DC Input Impedance 1.2x Attenuation (Low Additive Noise, ~5%) MCX terminated cable with wide variety of connections: • Solder-in (4 GHz) • Coaxial Cable to U.
ACTIVE VOLTAGE RAIL PROBE 4 GHz of Bandwidth Provides maximum bandwidth for probing near the CPU, Wide Assortment of Tips and Leads and the perfect match with the 4 GHz, 12 bit WavePro HD The RP4030 is supplied standard with solder-in and coaxial when making power integrity measurements. cables with MCX and U.FL PCB receptacle mounts. A browser tip is optionally available.
ACTIVE VOLTAGE PROBES 88
ACTIVE VOLTAGE PROBES Engineers must commonly probe high-frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit and distort signals at higher frequencies. Active voltage probes feature both high input R and low input C to reduce circuit loading across the entire probe/oscilloscope bandwidth.
ZS SERIES ACTIVE PROBES The ZS Series probes are high impedance, low capacitance active probes that maintain high signal fidelity through 4 GHz. A small form factor and a wide variety of accessories ensures the ZS probe meets every difficult probing challenge. Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies but inappropriately load the circuit and distort signals at higher frequencies.
ZS SERIES ACTIVE PROBES ZS1000 ZS1500 ZS2500 PK-ZS-010 Channel ID Colored Clips PACC-MS005 Freehand Probe Holderk PK-ZS-012 2.
CURRENT PROBES 12
CURRENT PROBES Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements. Wide Range of Applications Teledyne LeCroy current probes are available in a variety of models for a wide range of applications.
CURRENT PROBES Key Features • ProBus active probe interface withautomatic scaling in A/div • Autozero and degauss capabilities built into instrument’s user interface • Wide range of input currents and bandwidth capabilities Teledyne LeCroy Current Probe and Adapter Model Numbers: CP030 CP030A CP031 CP031A CP150 CP500 DCS025 CA10 CP030 30 Arms continuous current 50 Apeak current 50 MHz bandwidth – – – CP031 30 Arms continuous current 50 Apeak current 100 MHz bandwidth – – – CP150 150 Arms continuous
CURRENT PROBES CA10 Current Sensor Adapter The CA10 enables a third-party current measurement device to operate like a Teledyne LeCroy probe. The CA10 is programmable and customizable to work with third-party current measurement devices that output voltage or current signals proportional to measured current. (See page 48 for more information and specifications). Specifications Electrical Characteristics* Max. Continuous Input Current Bandwidth CP030 (CP030-3M) 50 MHz (10 MHz) ≤ 7 ns (≤ 35 ns) Max.
DIFFERENTIAL PROBES 16
DIFFERENTIAL PROBES Our differential probes are general purpose high-bandwidth probes with high dynamic range and offset. Wide variety of tips and leads are available, including solder-in, QuickLink solder-in, HiTemp solder-in, browser tip, square-pin, and SMA/SMP lead. Teledyne LeCroy Differential Probe Model Numbers: ≤ 1.
≤ 1.5 GHz DIFFERENTIAL PROBES The ZD Series probes provide wide dynamic range, excellent noise and loading performance and an extensive set of probe tips, leads, and ground accessories to handle a wide range of probing scenarios. The low 1 pF capacitance means this probe is ideal for all frequencies. The ZD Series differential probes provide full system bandwidth for all Teledyne LeCroy Oscilloscopes 1.5 GHz and lower. Fully Integrated Teledyne LeCroy ≤1.
≤ 1.5 GHz DIFFERENTIAL PROBES Ordering Information Product Description 200 MHz, 3.5 pF, 1 MΩ Active Differential Probe 500 MHz, 1.0 pF Active Differential Probe, ±8 V 1 GHz, 1.0 pF Active Differential Probe, ±8 V 1.5 GHz, 1.
4 GHz - 6 GHz DIFFERENTIAL PROBES Teledyne LeCroy’s WaveLink 4-6 GHz Differential Probes are a general purpose probing solution with high-input dynamic range and offset range capability. The range of capabilities is ideal for a variety of high-speed DDR signals where high dynamic range and large offset requirements are common.
4 GHz - 6 GHz DIFFERENTIAL PROBES Bandwidth* (Probe only, guaranteed) (System bandwidth, typical) Rise Time* (10–90%) Rise Time* (20–80%) Noise (System) Input Input Dynamic Range (Nominal) Input Common Mode Voltage Range (Nominal) Input Offset Voltage Range Non-destructive Input Range (Nominal) Attenuation DC Input Resistance (Nominal) D610-A-PB2, D610-A-PL D620-A-PB2, D620-A-PL D410-A-PB2 D420-A-PB2 Dx10-SI, Dx10-QL-SI, Dx10-HiTemp, Dx10-QC and Dx10-PT Tips 4 GHz Dx20-SI, Dx20-QL-SI, Dx20-HiTemp
8 GHz - 13 GHz DIFFERENTIAL PROBES The WaveLink Differential Probe Series is a 8-13 GHz bandwidth active differential probe series with high input dynamic range, a large offset capability, and a wide variety of tips and leads available for different applications. Key Features Teledyne LeCroy 8 GHz - 13 GHz Differential Probe Model Numbers: D830-PB2 D830-PL D1330-PL • Choice of 8 or 13 GHz bandwidth models • 3.
8 GHz - 13 GHz DIFFERENTIAL PROBES Bandwidth* (Probe only, guaranteed) (System bandwidth, typical) D830-PB2, D830-PL Dxx30-SI, Dxx30-QL-SI, Dxx30-SMA-SMP, Dxx30-HiTemp, and Dxx30-PT Tips 8 GHz Dxx30-SP Tip 3 GHz Rise Time* (10–90%) Dxx30-SI, Dxx30-QL-SI, Dxx30-SMA-SMP, Dxx30-HiTemp, and Dxx30-PT Tips 50 ps (typical) Dxx30-SP Tip 100 ps (typical) Noise (System) Input Impedance (Zmin, typical) Impedance (mid-band, typical) Dxx30-PT and Dxx30-HiTemp Tips 40 ps (typical) Dxx30-SP Tip 132 ps (typical)
8 GHz - 30 GHz DIFFERENTIAL PROBES The DH series of 8 to 30 GHz active differential probes provides high input dynamic range, large offset capability, low loading and excellent signal fidelity with a range of connection options. Key Features • Bandwidth models from 8 GHz to 30 GHz • Low loading and high impedance for minimal signal disturbance • Wide variety of tips: Teledyne LeCroy 8 GHz - 30 GHz Differential Probe Model Numbers: DH08-PB2 DH08-PL DH13-PL DH16-PL DH20-PL DH25-2.92MM DH30-2.
8 GHz - 30 GHz DIFFERENTIAL PROBES Bandwidth* Bandwidth (probe only) Bandwidth with DH-SI or DH-SI-HS tip Bandwidth with DH-HITEMP tip Bandwidth with DH-QL adapter and QL-SI tip Rise Time* Rise Time (10-90%) Rise Time (20-80%) Probe noise (referred to input) With DH-SI-HS tip With all other tips Probe noise density (referred to input) With DH-SI-HS tip With all other tips DH08 DH13 DH16 DH20 DH25 DH30 8 GHz 8 GHz 8 GHz 8 GHz 13 GHz 13 GHz 13 GHz 8 GHz 16 GHz 16 GHz 16 GHz 8 GHz 20 GHz 20 GHz 16 GH
HIGH VOLTAGE DIFFERENTIAL PROBES 26
HIGH VOLTAGE DIFFERENTIAL PROBES High voltage differential probes provide high CMRR over a broad frequency range to simplify the measurement challenges found in noisy, high commonmode power electronics environments. The probe’s design is easy-to-use and enables safe, precise high voltage floating measurements.
HIGH VOLTAGE DIFFERENTIAL PROBES Teledyne LeCroy High Voltage Differential Probe Model Numbers: HVD3102A HVD3106A HVD3106A-6M HVD3206A HVD3206A-6M HVD3605A The HVD3000A series high voltage differential probes provide high CMRR over a broad frequency range to simplify the measurement challenges found in noisy, high common-mode power electronics environments. The probe’s design is easy-to-use and enables safe, precise high voltage floating measurements.
HIGH VOLTAGE DIFFERENTIAL PROBES Bandwidth Differential Voltage Range Max Safe Input Voltage HVD3102A HVD3106A 25 MHz 1500 V (DC + peak AC) (1750V maximum typical measurable before saturation) 120 MHz Gain Accuracy Cable Length Included Tip Accessories HVD3106A-6M 80 MHz 1500 V (DC + peak AC) (2000V maximum typical measurable before saturation) HVD3206A HVD3206A-6M HVD3605A 120 MHz 80 MHz 100 MHz 7000 V (DC + peak AC) (7600 V maximum typical measurable before saturation) 8485 V (DC + peak AC) C
HIGH VOLTAGE DIFFERENTIAL PROBES Teledyne LeCroy High Voltage Differential Probe Model Numbers: HVD3102A HVD3106A HVD3106A-6M HVD3206A HVD3206A-6M HVD3605A AP031 Ordering Information 30 Product Description Product Code 1 kV, 25 MHz High Voltage Differential Probe with 2 m cable 1 kV, 120 MHz High Voltage Differential Probe with 2 m cable 1 kV, 80 MHz High Voltage Differential Probe with 6 m cable 1 kV, 25 MHz High Voltage Differential Probe with 2 m cable without tip Accessories 1 kV, 120 MHz High Vol
HIGH VOLTAGE DIFFERENTIAL PROBES AP031 The AP031 is a low cost, battery operated active differential probe intended for measuring higher voltages. The differential techniques employed permit measurements to be taken at two points in a circuit without reference to the ground, allowing the oscilloscope to be safely grounded without the use of opto-isolators or isolating transformers.
HIGH VOLTAGE PROBES 32
HIGH VOLTAGE PROBES High voltage probes are suitable for a wide range of applications where high-voltage measurements must be made safely and accurately. There are several fixed attenuation probes covering a range from 1 kV to 6 kV and varying transient overvoltage ratings. All of these high voltage probes feature a spring loaded probe tip and a variety of standard accessories to make probing high voltages safe and easy.
HIGH VOLTAGE PROBES The HVP120 is a high voltage passive probe designed for probing up to 1,000 Vrms and capable of handling up to 6,000 V peak transients. Its fast rise time and excellent frequency response make it suitable for a wide variety of high voltage measurement applications. The HVP120 features a spring loaded probe tip and a variety of standard accessories to make probing high voltages safe and easy.
HIGH VOLTAGE PROBES The PPE series includes four fixed-attenuation probes covering a range from 2 kV to 6 kV, and one switchable probe providing ÷10/÷100 attenuation for voltage inputs up to 1.2 kV. All fixed-attenuation, standard probes automatically rescale compatible Teledyne LeCroy oscilloscopes for the appropriate attenuation of the probe.
HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES 36
HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES The HVFO is an affordable, optimally designed probe for measurement of small signals floating on an HV bus in power electronics designs or for EMC, EFT, ESD, and RF immunity testing sensor monitoring. It far surpasses the measurement capabilities and signal fidelity of both conventional Teledyne LeCroy Probe Adapter Model Numbers: HVFO103 HV differential probes and acquisition systems that rely on galvanic high voltage isolation.
HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES The HVFO is an affordable, optimally designed probe for measurement of small signals floating on an HV bus in power electronics designs or for EMC, EFT, ESD, and RF immunity testing sensor monitoring. It far surpasses the measurement capabilities and signal fidelity of both conventional HV differential probes and acquisition systems that rely on galvanic high voltage isolation.
HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES Electrical Bandwidth Rise Time (10-90%) Input Dynamic Range 60 MHz (typical, with tip attached) 7.5 ns (typical) ±1V, ±5V, ±10V, ±20V, ±40V (DC+peak AC) respectively with 1X, 5X, 10X, 20X or 40X attenuating tips. All tips are purchased as accessories (none are included with HVFO103 probe).
OPTICAL-TO-ELECTRICAL CONVERTERS 40
OPTICAL-TO-ELECTRICAL CONVERTERS Teledyne LeCroy’s wide-band multi-mode optical-to-electrical converters are designed for measuring optical communications signals. Their broad wavelength range and multi-mode input optics make these devices ideal for applications including Ethernet, Fibre Channel, and ITU telecom standards. Available to support optical data rates up to 11.3 Gb/s with reference receivers, or slightly higher without reference receivers.
OPTICAL-TO-ELECTRICAL CONVERTERS Teledyne LeCroy Optical Probe Model Numbers: OE6250G-M OE695G OE425 OE455 OE525 OE555 OE6250G-M The OE6250G optical-to-electrical converter enables optical signal measurement of intensity-modulated signals up to 28 Gbaud and beyond on LabMaster or WaveMaster series real-time oscilloscopes. As a fully calibrated module, the OE6250G-M integrates seamlessly into the oscilloscope software to give optical intensity measurement straight out of the box.
OPTICAL-TO-ELECTRICAL CONVERTERS OE695G OE425/OE455/OE525/OE555 The OE695G wide-band optical-to-electrical converter is The O/E converters contain calibration data that can be ideal for measuring optical datacom and telecom signals used to create optical reference receivers for SONET/ with data rates from 622 Mb/s to 12.5+ Gb/s. Connection SDH (up to OC48/STM16), Fibre Channel, Gigabit Ether- to a real-time Teledyne LeCroy oscilloscope is through the net, and other optical standards.
PASSIVE PROBES 44
PASSIVE PROBES Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a ÷10 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400 V, some as high as 600 V.
PASSIVE PROBES Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe can be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
PASSIVE PROBES Passive Probe Accessories for PP019 and PP020 – Part numbers in blue Replacement Part Kit: PKIT4-5MM-101 PP024, PP025, and PP026 – Part numbers in gray Replacement Part Kit: PKIT6-5MM-101 Passive Probe Accessories for PP021, PP022, and PP023 Replacement Part Kit: PKIT5-2.5MM-101 PK5-PK6-001 Trimmer Tool PK4-5MM-5 PK5-PK6-001 Trimmer Tool PK5-PK6-002 Color Coding Rings (set) PK4-5MM-8 PK5-PK6-002 Color Coding Rings (set) PK5-2.
PROBE ADAPTERS Probe adapters provide simple and easy interface of third-party probes as well as change between the different Teledyne LeCroy Oscilloscope input and cable types (ProBus, ProLink, K/2.92 mm, BNC and SMA). Depending on the adapters, changing between the Teledyne LeCroy Oscilloscope’s input type may have an effect on the overall performance of the channel.
PROBE ADAPTERS Key Features • Allows TekProbe™ interface level II probes to work with any ProBus-equipped Teledyne LeCroy • • • • • TPA10 The TPA10 ProBus™ Probe Adapter enables you to connect select TekProbe interface level II probes to any ProBus-equipped Teledyne LeCroy instrument. The TPA10 supplies all necessary power and offset control to the probe and automatically detects which probe is attached. Specifications Electrical Characteristics Bandwidth Power Supplies Offset Voltage Max.
TRANSMISSION LINE PROBES Transmission line probes are a special type of passive probe designed for use at very high frequencies. They replace the high impedance probe cable found in a traditional passive probe with a precision transmission line, with a characteristic impedance that matches the oscilloscope input (50 Ω). This greatly reduces the input capacitance to a fraction of a picofarad, minimizing the loading of high frequency signals. A matching network at the tip increases the DC input resistance.
TRANSMISSION LINE PROBES PP066 The PP066 is a high-bandwidth passive probe designed for use with the WaveMaster and other high-bandwidth oscilloscopes with 50 Ω input termination. This very low capacitance probe provides an excellent solution for higher frequency applications, especially the probing of transmission lines with 20–100 Ω impedance.
1-800-5-LeCroy teledynelecroy.com Local sales offices are located throughout the world. Visit our website to find the most convenient location. © 2020 Teledyne LeCroy, Inc. All rights reserved. Specifications, prices, availability, and delivery subject to change without notice. Product or brand names are trademarks or requested trademarks of their respective holders.