Data Sheet
3
SPECIFICATIONS
Electrical Specications
Model T3RC0300-UM
T3RC0600-HF
T3RC3000-HF
T3RC3000-LF
T3RC6000-LF
Maximum di/dt ratings: peak
rms
70kA/us
1.2kA/us
100kA/us
1.2kA/us
11kA/us
0.8kA/us
Calibration
Accuracy: Variation with conductor
position in the coil
+ 2% + 2% + 1%
Accuracy: Linearity of current
magnitude
0.05% or Reading 0.05% of Reading 0.05% of Reading
Temperature: Coil and Cable -40C to +125C -40C to +125C -20C to +100C
Temperature: Integrator 0C to +40C 0C to +40C 0C to +40C
Calibrated to + 0.2% reading with conductor central in the coil loop
Probe Coil Size
80mm
T3RC0600-HF: 100mm
T3RC3000-HF: 200mm
300mm
Ordering Information
Ordering Information
Model Number Measurement Current Bandwidth
T3RC0300-UM Up to 300 Amps
9.2 Hz to 30 MHz
T3RC0600-HF Up to 600 Amps
12 Hz to 30 MHz
T3RC3000-HF Up to 3000 Amps
3 Hz to 23 MHz
T3RC3000-LF Up to 3000 Amps
0.11 Hz to 6.5 MHz
T3RC6000-LF Up to 6000 Amps
0.055 Hz to 6.5 MHz
All probes come complete with a set of batteries, a power line adapter, a BNC cable and a storage box.
The probe and it’s parts are covered by a 1 year return to Teledyne LeCroy warranty.