Owner manual

TA660 User's Manual Catalyst Enterprises, Inc
99
Figure 90 Signal Color Selection Dialog
Latency Report
To view Master/Target Latencies add the signals LAT_XX to the
display See Figure 88.
Using the Cursors
Each of the data displays incorporates three cursors that are labeled X,
Y and T. All of them are initially overlaid and positioned at location
0, which is the trigger position of the display. The Trigger or T cursor
is always locked at location 0 of the display. It cannot be repositioned.
and serves as the measurement reference.
Moving the X Cursor The X cursor may be dragged by selecting the left mouse
button and positioning the mouse cursor over the display
cursors and then dragging to the desired location or by
clicking the left mouse button with the mouse cursor
positioned anywhere in the display. This will cause a
display in the [X-T](XRef-Trig) box to show the difference
in clocks, or, if selected, time, between the trigger and the X
cursor.
Moving the Y Cursor Similarly the Y cursor may be dragged by positioning the
mouse cursor over the cursors with the right mouse button
selected or by clicking the right mouse button with the
mouse cursor anywhere in the display. This will cause a
display in the [Y-T](YRef-Trig) box to show the difference