Owner manual

TA660 User's Manual Catalyst Enterprises, Inc
5
Installing Your Analyzer
Hardware Installation
1. Make sure that the Target Machine is powered down.
2. Remove the case from your machine in accordance with the
instructions supplied for it.
3. Install the Analyzer card in any available PCI slot and secure the
mounting bracket to the chassis with the mounting screw.
Warning: Make sure to take precautions to avoid static electricity
discharge damage to the Analyzer Card by using a
grounding strap or touching a grounded metal surface just
prior to handling the analyzer card. Avoid touching any
components and handle card by the edges only.
4. Interconnect the Analyzer DB-25 connector to the Host system Bi-
directional parallel port using the provided DB-25 pin cable.
Host and Target Same The Analyzer may be used in a configuration such that the
Host and Target are the same machine.
Bi-Directional Port The Analyzer requires that The Host parallel port support
Bi-directional data transfers. See LPT Port Setting for
verifying that your parallel port supports and/or is set to a
Bi-directional mode. If the parallel port on your Host
system does not support Bi-directional data transfers you
must then install the parallel port card supplied with your
analyzer in a spare ISA slot and connect to it.
Port Configuration The parallel port card supplied with your analyzer is pre
configured for LPT2 (H278). If the Host system is using this
address for its printer port, you must then change the jumper
configuration on the ISA parallel card to H378 (LPT1).