Owner manual

TA660 User's Manual Catalyst Enterprises, Inc
39
Figure 33 Read/Modify Write Dialog Box
1. Enter an address the contents of which you wish to modify in the
Current Address edit box.
2. Enter the value to be written to that address in the New Value edit
box.
NOTE: This feature makes the TA660 to be a bus master and
may be used to read or write any registers or memory contents
of a target device without having to set the programming menu.
Write Read Verify
To perform write read verify select Write/Read Verify . . .from
the Exerciser dropdown list on the menu bar. This will open the
Write/Read verify dialog box.
Figure 34 Write/Read Verify Dialog Box
1. Select the command type from the Command dropdown list, enter
the Target address, BE and either the data to be written or a
previously defined data block and a DMA size.