Oscilloscope Probes and Probe Accessories
PROBE SELECTION GUIDE Teledyne LeCroy has a wide variety of world class probes and amplifiers to compliment its product line. From the ZS high impedance active probes to the WaveLink differential probing system which offers bandwidths up to 25 GHz, Teledyne LeCroy probes and probe accessories provide optimum mechanical connections for signal measurement.
Os cill osc ope Wa s veJ et O sci llos cop Wa es veS urf er 3 000 Wa Os cill MX veSu osc s-B rfe ope r Os 10 s cill / M osc Xs HD ope -B Hig O400 /M s hD 0/ SO efin HD itio O4 n O 000 Wa sci -M Os veRu llos S cill nne cop osc r 6 es ope Zi s HD Hig O600 hD 0/ efin HD itio O60 n O 00 HD sci -MS O llos Hig 800 hD 0/ cop efin HD es itio O80 n O 00 sci -MS MD llos A8 00 cop Mo es tor Dri ve HR An O1 aly 2-b zer it O s sci Wa l l o v s e c Os Pro ope cill s osc /SDA / ope DD A s /7 Wa Zi/ 7Z Os veMa i-A cill ste
ACTIVE VOLTAGE PROBES 44
ACTIVE VOLTAGE PROBES Engineers must commonly probe high-frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit and distort signals at higher frequencies. Active voltage probes feature both high input R and low input C to reduce circuit loading across the entire probe/oscilloscope bandwidth.
ZS SERIES ACTIVE PROBES The ZS Series probes are high impedance, low capacitance active probes that maintain high signal fidelity through 4 GHz. A small form factor and a wide variety of accessories ensures the ZS probe meets every difficult probing challenge. Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies but inappropriately load the circuit and distort signals at higher frequencies.
ZS SERIES ACTIVE PROBES PK-ZS-010 Channel ID Colored Clips ZS1000 ZS1500 ZS2500 PACC-MS005 Freehand Probe Holderk PK-ZS-012 2.
CURRENT PROBES 8
CURRENT PROBES Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements. Wide Range of Applications Teledyne LeCroy current probes are available in a variety of models for a wide range of applications.
CURRENT PROBES Features • ProBus active probe interface withautomatic scaling in A/div • Autozero and degauss capabilities built into instrument’s user interface • Wide range of input currents and bandwidth capabilities Teledyne LeCroy Current Probes Model Numbers: CP030 CP030A CP031 CP031A CP150 CP500 DCS015 • CP030 – 30 A continuous current A current – 50 50 – MHz bandwidth rms • CP030A A continuous current – 30 50 – 50 AMHzcurrent – 1 mA/divbandwidth sensitivity – rms peak • • CP031 – –
CURRENT PROBES Specifications CP030† CP030A† CP031† CP031A† CP150 CP500 150 Arms 500 Arms Electrical Characteristics* Max. Continuous Input Current Bandwidth Rise Time (typical) Max. Peak Current (non-continuous) Output Voltage Max Continuous Input Current at 1 V/A (100mA/div or less) Offset Range at 1V/A (100mA/div or less) Minimum Sensitivity Low-Frequency Accuracy AC Noise at 20 MHz BWL Coupling 30 Arms 50 MHz ≤ 7 ns 100 MHz ≤ 3.
DIFFERENTIAL PROBES 12
DIFFERENTIAL PROBES Teledyne LeCroy Differential Probes Model Numbers: Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point. ≤ 1.
≤ 1.5 GHz DIFFERENTIAL PROBES The ZD Series probes provide wide dynamic range, excellent noise and loading performance and an extensive set of probe tips, leads, and ground accessories to handle a wide range of probing scenarios. The low 1 pF capacitance means this probe is ideal for all frequencies. The ZD Series differential probes provide full system bandwidth for all Teledyne LeCroy Oscilloscopes 1.5 GHz and lower. Fully Integrated Teledyne LeCroy ≤1.
≤ 1.5 GHz DIFFERENTIAL PROBES Ordering Information Product Description 200 MHz, 3.5 pF, 1 MΩ Active Differential Probe 500 MHz, 1.0 pF, 1 MΩ Active Differential Probe 1 GHz, 1.0 pF, 1 MΩ Active Differential Probe 1.5 GHz, 1.
4 GHz - 6 GHz DIFFERENTIAL PROBES WaveLink® probes provide industry leading technology for wideband signal connection to test instruments. The first differential probes to employ SiGe technology, they deliver full system bandwidth when used with oscilloscopes up to 6 GHz.
4 GHz - 6 GHz DIFFERENTIAL PROBES Bandwidth* (Probe Only, Guaranteed) (System Bandwidth, Typical) Rise Time* (10–90%) Rise Time* (20–80%) Noise (System) Input Input Dynamic Range (Nominal) Input Common Mode Voltage Range (Nominal) Input Offset Voltage Range Non-destructive Input Range (Nominal) Attenuation DC Input Resistance (Nominal) Impedance (Zmin, Typical) D610, D610-PS D620, D620-PS Dx20-SI and Dx20-PT Tips 6 GHz Dx10-SI, Dx10-HiTemp, Dx10-QC and Dx10-PT Tips 4 GHz Dx20-SI, Dx20-HiTemp, Dx20-
8 GHz - 13 GHz DIFFERENTIAL PROBES General Purpose Probe with Range of Capabilities Teledyne LeCroy’s WaveLink 8-13 GHz Differential Probes are a medium bandwidth, general purpose probing solution with high input dynamic range and offset range capability. These probes support solder-in, positioner (browser), square pin and SMA/SMP cabled tip/lead connections. The range of capabilities is ideal for a variety of high speed DDR signals where high dynamic range and large offset requirements are common.
8 GHz - 13 GHz DIFFERENTIAL PROBES Bandwidth Rise Time (10–90%) Rise Time (20–80%) Noise (Probe) Noise (System) D830, D830-PS D1030, D1030-PS D1330, D1330-PS Dxx30-SI, Dxx30-SMA-SMP, and Dxx30-PT Tips 8 GHz (probe only, guaranteed) 8 GHz (system bandwidth, when used with 808Zi/Zi-A, typical) Dxx30-SI, Dxx30-SMA-SMP, and Dxx30-PT Tips 10 GHz (probe only, guaranteed) 10 GHz (system bandwidth, when used with 813Zi/Zi-A, typical) Dxx30-SI and Dxx30-SMA-SMP Tips 13 GHz (probe only, guaranteed) 13 GHz (s
13 GHz - 25 GHz DIFFERENTIAL PROBES Ultra-wideband Architecture for Superior Signal Fidelity Teledyne LeCroy’s WaveLink® high bandwidth differential probes utilize advanced differential traveling wave (distributed) amplifier architecture to achieve superior high frequency true analog broadband performance. Traveling wave (distributed) amplifiers are commonly used in ultra high frequency broadband amplifiers.
13 GHz - 25 GHz DIFFERENTIAL PROBES Bandwidth D1305-A, D1305-A-PS Dxx05-SI and Dxx05-PT Tips 13 GHz (probe only, guaranteed) 13 GHz (system bandwidth, when used with 813Zi, typical) D1605-A, D1605-A-PS Dxx05-SI and Dxx05-PT Tips 16 GHz (probe only, guaranteed) 16 GHz (system bandwidth, when used with 816Zi, typical) D2005-A, D2005-A-PS Dxx05-SI and Dxx05-PT Tips 20 GHz (probe only, guaranteed) 20 GHz (system bandwidth, when used with 820Zi, typical) Rise Time (10–90%) Dxx05-SI and Dxx05-PT Tips 32.
HIGH VOLTAGE DIFFERENTIAL PROBES 22
HIGH VOLTAGE DIFFERENTIAL PROBES Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point.
HIGH VOLTAGE DIFFERENTIAL PROBES Teledyne LeCroy High Voltage Differential Probe Model Numbers: HVD3102 HVD3106 HVD3106-6M The HVD3000 high voltage differential probes provide high CMRR over a broad frequency range to simplify the measurement challenges found in noisy, high common-mode power electronics environments. The probe’s design is easy-to-use and enables safe, precise high voltage floating measurements.
HIGH VOLTAGE DIFFERENTIAL PROBES Specifications Bandwidth Rise Time (10-90) Differential Voltage Range Common Mode Voltage Range Maximum Input Voltage to Earth Max Safe Input Sensitivity Gain Accuracy Slew Rate Attenuation Input Impedance Input Coupling Output Coupling Output Termination Interface Input Lead Length Cable Length (input lead to oscilloscope connection) Noise and Rejection CMRR (Typical) Noise (Probe) Environmental Temperature (Operating) Temperature (Non-Operating) Humidity (Operating)
HIGH VOLTAGE DIFFERENTIAL PROBES Teledyne LeCroy High Voltage Differential Probes Model Numbers: AP031 ADP300 ADP305 The AP031 is a low cost, battery operated active differential probe intended for measuring higher voltages. The differential techniques employed permit measurements to be taken at two points in a circuit without reference to the ground, allowing the oscilloscope to be safely grounded without the use of opto-isolators or isolating transformers.
HIGH VOLTAGE DIFFERENTIAL PROBES ADP30X high-voltage active probes are safe, easy-to-use, and ideally suited for measuring power electronics. The ADP300 is designed for troubleshooting low-frequency power devices and other circuits where the reference potential is elevated from the ground or the location of the ground is unknown. The ADP305 is designed for measuring the high-speed floating voltages found in today’s power electronics.
DIFFERENTIAL AMPLIFIERS 28
DIFFERENTIAL AMPLIFIERS Teledyne LeCroy Differential Amplifier and Accessory Model Numbers: Differential amplifiers are intended to act as signal conditioning preamplifiers for oscilloscopes and network and spectrum analyzers, providing differential measurement capability to instruments having only a single-ended input. The “-PR2” version of each amplifier is a dual channel unit. The DXC series differential input cables are matched to the characteristics of the amplifier.
DIFFERENTIAL AMPLIFIERS Teledyne LeCroy Differential Amplifier and Accessory Model Numbers: DA1855A DA1855-PR2 DA1855A-RM DA1855A-PR2-RM DXC5100 DXC100A DXC200 DA101 DA1855A The DA1855A is a stand-alone, high- in proportion to their attenuation ratio performance 100 MHz differential but do not exceed their maximum input amplifier. It is intended to act as a voltage rating.
DIFFERENTIAL AMPLIFIERS DXC100A ÷100 or ÷10 Selectable, 250 MHz Passive Differential Probe Pair • DC to 100 MHz Bandwidth with DA1855A DC to 10 MHz Bandwidth with DA1822 • Max Input Voltage 500 V • Selectable 10 or 100 Attenuation Factor • 1.2 m Cable Length DXC200 ÷1, 50 MHz, Passive Differential Probe Pair • DC to 50 MHz with DA1855A DC to 10 MHz with DA1822A • Max Input Voltage 500 V (Limited to Amplifier Max Input Voltage) • x1 Differential Probe Pair • 0.7 m Cable Length DXC5100 ÷100, 2.
HIGH VOLTAGE PROBES 32 32
HIGH VOLTAGE PROBES High voltage probes are suitable for a wide range of applications where high-voltage measurements must be made safely and accurately. There are several fixed attenuation probes covering a range from 1 kV to 6 kV and varying transient overvoltage ratings. All of these high voltage probes feature a spring loaded probe tip and a variety of standard accessories to make probing high voltages safe and easy.
HIGH VOLTAGE PROBES Teledyne LeCroy High Voltage Probe Model Number: HVP120 The HVP120 is a high voltage passive probe designed for probing up to 1,000 Vrms and capable of handling up to 6,000 V peak transients. Its fast rise time and excellent frequency response make it suitable for a wide variety of high voltage measurement applications. The HVP120 features a spring loaded probe tip and a variety of standard accessories to make probing high voltages safe and easy.
HIGH VOLTAGE PROBES HVP120 RMS vs.
HIGH VOLTAGE PROBES Teledyne LeCroy High Voltage Probe Model Numbers: PPE1.2KV PPE2KV PPE4KV PPE5KV PPE6KV The PPE series includes four fixed-attenuation probes covering a range from 2 kV to 6 kV, and one switchable probe providing ÷10/÷100 attenuation for voltage inputs up to 1.2 kV. All fixed-attenuation, standard probes automatically rescale compatible Teledyne LeCroy oscilloscopes for the appropriate attenuation of the probe. Features • • Safe, accurate high-voltage measurement 1.
HIGH VOLTAGE PROBES Trimming Tool Security Ground Lead Ground Lead (22 cm) Flexible 4 mm Security Adapter BNC Adapter Insulating Tip IC Insulating Tip Straight Tip (0.8 mm) Spring Contact Tip (0.8 mm) Sprung Hook Crocodile Clip (Black) Crocodile Clip (Red) Ordering Information Product Description ÷10/÷100; 200/300 MHz; 5 MΩ/50 MΩ High-Voltage Probe, 600 V/1.2 kV max. Voltage DC ÷100; 400 MHz; 50 MΩ High-Voltage Probe, 2 kV max.
OPTICAL PROBES 38
OPTICAL PROBES Teledyne LeCroy’s wide-band multi-mode optical-to-electrical converters are designed for measuring optical communications signals. Their broad wavelength range and multi-mode input optics make these devices ideal for applications including Ethernet, Fibre Channel, and ITU telecom standards. Available to support optical data rates up to 11.3 Gb/s with reference receivers, or slightly higher without reference receivers.
OPTICAL PROBES OE695G Teledyne LeCroy’s OE695G wide-band optical-to-electrical converter is ideal for measuring optical datacom and telecom signals with data rates from 622 Mb/s to 12.5+ Gb/s. Connection to a real-time Teledyne LeCroy oscilloscope is through the 2.92mm interface, with a provided adapter to connect to ProLink interfaces.
OPTICAL PROBES OE425/OE455/OE525/OE555 The O/E converters contain calibration data that can be used to create optical reference receivers for SONET/SDH (up to OC48/STM16), Fibre Channel, Gigabit Ethernet, and other optical standards. This feature is available when the O/E is used on a supported oscilloscope. The universal reference receiver supports any data rate up to 3 GHz and remains calibrated on any channel of the oscilloscope. Features • Frequency range to 5 GHz (6 GHz optical) • 62.
PASSIVE PROBES 42
PASSIVE PROBES Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a ÷10 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400 V, some as high as 600 V.
PASSIVE PROBES Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe can be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
PASSIVE PROBES Passive Probe Accessories for PP009, and PP011 Series PK1-5MM-105 IC-Cap 5.0 Insulating Cap PK1-5MM-108 IC-Cap 5.0 2.54 mm pitch; black PK1-5MM-103 Adjustment Tool Protection Cap 5.0 black 5.8 mm 1.5 mm PK1-5MM-107 PCB Adapter 5.0 K1-5MM-106 Set Coding Rings 3x4 colors 1.0 mm x 4 PK1-5MM-102 Ground Lead 11 cm PK1-5MM-104 Rigid Tip 0.8 mm PK1-5MM-117 Flexible Adapter 5.0 to 5 mm banana plug PK1-5MM-101 Sprung Hook II 5.0 black PK1-5MM-118 Ground Spring 5.0 PK1-5MM-113 Pico hook \U+21
TRANSMISSION LINE PROBES Transmission line probes are a special type of passive probe designed for use at very high frequencies. They replace the high impedance probe cable found in a traditional passive probe with a precision transmission line, with a characteristic impedance that matches the oscilloscope input (50 Ω). This greatly reduces the input capacitance to a fraction of a picofarad, minimizing the loading of high frequency signals. A matching network at the tip increases the DC input resistance.
TRANSMISSION LINE PROBES PP066 The PP066 is a high-bandwidth passive probe designed for use with the WaveMaster and other high-bandwidth oscilloscopes with 50 Ω input termination. This very low capacitance probe provides an excellent solution for higher frequency applications, especially the probing of transmission lines with 20–100 Ω impedance.
1-800-5-LeCroy teledynelecroy.com Local sales offices are located throughout the world. Visit our website to find the most convenient location. © 2015 Teledyne LeCroy, Inc. All rights reserved. Specifications, prices, availability, and delivery subject to change without notice. Product or brand names are trademarks or requested trademarks of their respective holders.