User's Manual
Table Of Contents
- Introduction
- ETRX1 Function Summary
- Product Approvals
- Frequently Asked Questions
- Absolute Maximum Ratings
- Operating Conditions
- Electrical Specifications
- Functional Description
- AT Style Command Conventions
- AT+XXX?
- Using parameters
- AT Command Syntax
- Command Overview
- Module Control & Configuration Commands
- Z – Software Reset
- ATZ
- &F – Restore Factory Defaults
- AT&F
- +REMZ – Reset Remote Node
- AT+REMZ:
- OK
- ERROR
- I – Display Product Identification Information
- ATI
- TELEGESIS
- Ryyy
- OK
- +BLOAD – Enter the bootloader menu
- AT+BLOAD
- +CLONE – Clone Local node to remote node
- AT+CLONE:
,cccccccc - Cloning…
- or
- ERROR
- +TEST – Run self test
- AT+TEST
- OK
- ERROR
- Sn – S-Register access
- ATSn?
- OK or ERROR
- ATSn=
- OK or ERROR
- +PDWN – Power control
- AT+PDWN?
- AT+PDWN=
- OK or ERROR
- +BTABLE – Display the devices binding table
- AT+BTABLE?
- OK or ERROR
- +COO – Display the devices Coordinator
- AT+COO?
- OK or ERROR
- +ESCAN – Scan the energy of the current channel
- AT+ESCAN?
- +ESCAN:XX
- OK or ERROR
- ATZ
- Z – Software Reset
- Communication Commands
- +SN – Scan Network for other nodes
- AT+SN
- OK or ERROR
- +EN – Establish PANetwork
- AT+EN
- OK or ERROR
- PAN:
- +SORPHAN – Scan for orphans
- AT+SORPHAN
- OK or ERROR
- PAN:
- +EBN – Establish PANetwork using beacons
- AT+EBN
- OK or ERROR
- +SNEIGHBOURS – Scan for Neighbours
- AT+SNEIGHBOURS:XX
- OK or ERROR
- +PING – Indicate presence in the network
- AT+PING
- OK or ERROR
- +ASS – Associate Remote Node
- AT+ASS:
- OK or ERROR
- PAN:
- +ASACK – Accept association request from coordinator
- AT+ASACK:
- OK or ERROR
- PAN:
- +DASSR – Disassociate remote device from PAN
- AT+DASSR:
- OK or ERROR
- Instruct remote device to leave the PAN.
- +DASSL – Disassociate local device from PAN
- AT+DASSL
- OK or ERROR
- Instruct local device to leave the PAN.
- +BCAST – Transmit a Broadcast
- AT+BCAST:
- OK or ERROR
- BCAST:
= - +UCAST – Transmit a Unicast
- AT+UCAST:
, - OK or ERROR
- +CCAST – Transmit a Unicast to the Coordinator
- AT+CCAST:
- OK or ERROR
- +COST – Cost to talk to remote node
- AT+COST:
? - OK
- or
- ERROR
- +OPCHAN – Opens a channel to a remote node
- AT+OPCHAN:
- OK or ERROR
- AT+OPCHAN:01234567890ABCDEF
- ERROR
- CHAN:
- AT+ACKCHAN – Accept Channel
- AT+ACKCHAN
- OK or ERROR
- CHAN:
- AT+ACKCHAN
- +++ – Close channel and leave transmit terminal mode
- +++
- Close or ERROR
- Close
- SREMn – Remote S-Register access
- ATSREMn:
? - ERROR
- ATSREMn:
= - OK
- ERROR
- TOKDUMP – Display all S-Registers
- AT+TOKDUMP
- ERROR
- OK or ERROR
- AT+SN
- +SN – Scan Network for other nodes
- I/O Commands
- S-Registers
- S-Register Overview
- Standard S-Registers
- S0 – Channel Number
- R/W LOCAL
- R/W REMOTE
- After Soft or Hard Reset
- 7
- S1 – PAN ID
- R/W LOCAL
- R/W REMOTE
- After Soft or Hard Reset
- 2A2A
- S2 – Transmit Power Level
- R/W LOCAL
- R/W REMOTE
- After Soft or Hard Reset
- -1
- S3 – Baudrate
- R/W LOCAL
- R/W REMOTE
- S4 – Data Direction of I/O Port
- R/W LOCAL
- R/W REMOTE
- Defined in SD
- S5 – Output Buffer of I/O Port
- R/W LOCAL
- R/W REMOTE
- S6 – Input Buffer of I/O Port
- R LOCAL
- R REMOTE
- S7 – Encryption Key
- W LOCAL
- After Soft or Hard Reset
- R/W REMOTE
- R/W LOCAL
- S0 – Channel Number
- Extended S-Registers
- S8 – Main Function
- R/W LOCAL
- R/W REMOTE
- 00
- S9 – Operation of the special function pin
- R/W LOCAL
- R/W REMOTE
- XXXX
- SA – Functionality at start-up
- R/W LOCAL
- R/W REMOTE
- XX
- CDATA:
=XX,YYY,ZZZ - SB – Timer at start-up
- R/W LOCAL
- R/W REMOTE
- XX
- 0A
- SC – Clone Password
- W LOCAL
- TG-ETRX1
- SD – Initial Setting of S4
- R/W LOCAL
- R/W REMOTE
- After Soft or Hard Reset
- F8
- SE – Initial Setting of S5
- R/W LOCAL
- R/W REMOTE
- After Soft or Hard Reset
- F0
- SF – Initial Setting of S9
- R/W LOCAL
- R/W REMOTE
- 0000
- SG – User Readable Name
- R/W LOCAL
- R/W REMOTE
- NoName
- R/W REMOTE
- R/W LOCAL
- S8 – Main Function
- List of Error codes
- Physical Dimensions
- Recommended Footprint
- Ordering Information
- Trademarks
- Disclaimer
- Contact Information
- References
Telegesis (UK) Limited
TG-ETRX1-PM-01-106 16
ETRX1
Preliminary Product Manual 1.06
9.2.1. Module Control & Configuration Commands
Z – Software Reset
Execute Command
ATZ
Response
Module Performs a software reset
All S Registers keep the user defined values
SW release
R100
&F – Restore Factory Defaults
Execute Command
AT&F
Response
Module Performs a software reset
All non volatile S Registers are updated with the
factory defaults
SW release
R100
+REMZ – Reset Remote Node
Execute Command
AT+REMZ:<EUI64>
Use on:
Coordinator
FFD’s
RFD’s
Response
OK
or
ERROR<errorcode>
<errorcode> represents the error code explained
in section 11. On receiving this command the
remote node will soft reset itself. Note: If the
remote node is an FFD, packets which are
currently relayed by this node may get lost.
SW release
R103
I – Display Product Identification Information
Execute Command
ATI
Response
TELEGESIS
Ryyy
<EUI64>
OK
Where yyy is the software revision and <EUI64> is
the IEEE 802.15.4 identifier
SW release
R100
©2005 Telegesis (UK) Ltd ETRX1 Product Manual (Rev 1.06)