User's Manual
Table Of Contents
- Introduction
- ETRX1 Function Summary
- Product Approvals
- Frequently Asked Questions
- Absolute Maximum Ratings
- Operating Conditions
- Electrical Specifications
- Functional Description
- AT Style Command Conventions
- AT+XXX?
- Using parameters
- AT Command Syntax
- Command Overview
- Module Control & Configuration Commands
- Z – Software Reset
- ATZ
- &F – Restore Factory Defaults
- AT&F
- +REMZ – Reset Remote Node
- AT+REMZ:
- OK
- ERROR
- I – Display Product Identification Information
- ATI
- TELEGESIS
- Ryyy
- OK
- +BLOAD – Enter the bootloader menu
- AT+BLOAD
- +CLONE – Clone Local node to remote node
- AT+CLONE:
,cccccccc - Cloning…
- or
- ERROR
- +TEST – Run self test
- AT+TEST
- OK
- ERROR
- Sn – S-Register access
- ATSn?
- OK or ERROR
- ATSn=
- OK or ERROR
- +PDWN – Power control
- AT+PDWN?
- AT+PDWN=
- OK or ERROR
- +BTABLE – Display the devices binding table
- AT+BTABLE?
- OK or ERROR
- +COO – Display the devices Coordinator
- AT+COO?
- OK or ERROR
- +ESCAN – Scan the energy of the current channel
- AT+ESCAN?
- +ESCAN:XX
- OK or ERROR
- ATZ
- Z – Software Reset
- Communication Commands
- +SN – Scan Network for other nodes
- AT+SN
- OK or ERROR
- +EN – Establish PANetwork
- AT+EN
- OK or ERROR
- PAN:
- +SORPHAN – Scan for orphans
- AT+SORPHAN
- OK or ERROR
- PAN:
- +EBN – Establish PANetwork using beacons
- AT+EBN
- OK or ERROR
- +SNEIGHBOURS – Scan for Neighbours
- AT+SNEIGHBOURS:XX
- OK or ERROR
- +PING – Indicate presence in the network
- AT+PING
- OK or ERROR
- +ASS – Associate Remote Node
- AT+ASS:
- OK or ERROR
- PAN:
- +ASACK – Accept association request from coordinator
- AT+ASACK:
- OK or ERROR
- PAN:
- +DASSR – Disassociate remote device from PAN
- AT+DASSR:
- OK or ERROR
- Instruct remote device to leave the PAN.
- +DASSL – Disassociate local device from PAN
- AT+DASSL
- OK or ERROR
- Instruct local device to leave the PAN.
- +BCAST – Transmit a Broadcast
- AT+BCAST:
- OK or ERROR
- BCAST:
= - +UCAST – Transmit a Unicast
- AT+UCAST:
, - OK or ERROR
- +CCAST – Transmit a Unicast to the Coordinator
- AT+CCAST:
- OK or ERROR
- +COST – Cost to talk to remote node
- AT+COST:
? - OK
- or
- ERROR
- +OPCHAN – Opens a channel to a remote node
- AT+OPCHAN:
- OK or ERROR
- AT+OPCHAN:01234567890ABCDEF
- ERROR
- CHAN:
- AT+ACKCHAN – Accept Channel
- AT+ACKCHAN
- OK or ERROR
- CHAN:
- AT+ACKCHAN
- +++ – Close channel and leave transmit terminal mode
- +++
- Close or ERROR
- Close
- SREMn – Remote S-Register access
- ATSREMn:
? - ERROR
- ATSREMn:
= - OK
- ERROR
- TOKDUMP – Display all S-Registers
- AT+TOKDUMP
- ERROR
- OK or ERROR
- AT+SN
- +SN – Scan Network for other nodes
- I/O Commands
- S-Registers
- S-Register Overview
- Standard S-Registers
- S0 – Channel Number
- R/W LOCAL
- R/W REMOTE
- After Soft or Hard Reset
- 7
- S1 – PAN ID
- R/W LOCAL
- R/W REMOTE
- After Soft or Hard Reset
- 2A2A
- S2 – Transmit Power Level
- R/W LOCAL
- R/W REMOTE
- After Soft or Hard Reset
- -1
- S3 – Baudrate
- R/W LOCAL
- R/W REMOTE
- S4 – Data Direction of I/O Port
- R/W LOCAL
- R/W REMOTE
- Defined in SD
- S5 – Output Buffer of I/O Port
- R/W LOCAL
- R/W REMOTE
- S6 – Input Buffer of I/O Port
- R LOCAL
- R REMOTE
- S7 – Encryption Key
- W LOCAL
- After Soft or Hard Reset
- R/W REMOTE
- R/W LOCAL
- S0 – Channel Number
- Extended S-Registers
- S8 – Main Function
- R/W LOCAL
- R/W REMOTE
- 00
- S9 – Operation of the special function pin
- R/W LOCAL
- R/W REMOTE
- XXXX
- SA – Functionality at start-up
- R/W LOCAL
- R/W REMOTE
- XX
- CDATA:
=XX,YYY,ZZZ - SB – Timer at start-up
- R/W LOCAL
- R/W REMOTE
- XX
- 0A
- SC – Clone Password
- W LOCAL
- TG-ETRX1
- SD – Initial Setting of S4
- R/W LOCAL
- R/W REMOTE
- After Soft or Hard Reset
- F8
- SE – Initial Setting of S5
- R/W LOCAL
- R/W REMOTE
- After Soft or Hard Reset
- F0
- SF – Initial Setting of S9
- R/W LOCAL
- R/W REMOTE
- 0000
- SG – User Readable Name
- R/W LOCAL
- R/W REMOTE
- NoName
- R/W REMOTE
- R/W LOCAL
- S8 – Main Function
- List of Error codes
- Physical Dimensions
- Recommended Footprint
- Ordering Information
- Trademarks
- Disclaimer
- Contact Information
- References
Telegesis (UK) Limited
TG-ETRX1-PM-01-106 21
ETRX1
Preliminary Product Manual 1.06
+SORPHAN – Scan for orphans
Execute Command
AT+SORPHAN
Use on:
Coordinator
Note:
When issuing this command the local device
becomes a Coordinator and bits 1-0 in S8
are set 10 (coordinator).
There should only be a single coordinator on
a PAN.
Response
OK or ERROR<errorcode>
FFD:<EUI64>
RFD:<EUI64>
<errorcode> represents the error code explained in
section 11.
Actively Scans the network and requests all
devices in the same channel and PAN ID which are
not associated with this particular coordinator to
report within a few seconds. Any devices reporting
back are asked to join the PAN in case bit 3 in S8
is not set. If bit 3 in S8 is set use AT+ASS to ask
them to join the PAN.
The prefix FFD or RFD indicates the devices
functionality as defined by the remote S8. Note
that any nodes will not respond if in a power down
mode higher than 0.
Remote Action
Will only take place if bit 3 in S8 is not set on
the coordinator.
Prompt
Depending on the setting of bit 2 in the remote S8
If unset the node will automatically join the PAN
(default)
<NO ACTION>
if set the node will display the request in the format
PAN:<EUI64>
The remote device has to acknowledge the request
using the command AT+ASACK in order to join the
PAN.
SW release
R100
©2005 Telegesis (UK) Ltd ETRX1 Product Manual (Rev 1.06)