Product Manual

sETRX357-LRS Family
©2014 Telegesis (UK) Ltd - 31 - sETRX357-LRS Product Manual
15 Reliability Tests
The following measurements have been conducted after the module has been exposed to
standard room temperature and humidity for 1 hour.
No
Item
Limit
Condition
1 Vibration test
Electrical parameter should be
in specification
Freq.:40Hz,Amplitude:1.5mm
20min. / cycle,1hrs. each of X and Y axis
2 Shock test the same as the above
Dropped onto hard wood from height of
50cm for 10 times
3 Heat cycle test the same as the above
-40°C for 30min. and +85°C for 30min.;
each temperature 300 cycles
5 Low temp. test the same as the above -40°C, 300h
6 High temp. test the same as the above +85°C, 300h
Table 19: Reliability Tests
16 Application Notes
16.1 Safety Precautions
These specifications are intended to preserve the quality assurance of products as individual
components.
Before use, check and evaluate their operation when mounted on your products. Abide by
these specifications when using the products. These products may short-circuit. If electrical
shocks, smoke, fire, and/or accidents involving human life are anticipated when a short
circuit occurs, then provide the following failsafe functions as a minimum:
(1) Ensure the safety of the whole system by installing a protection circuit and a protection
device.
(2) Ensure the safety of the whole system by installing a redundant circuit or another
system to prevent a single fault causing an unsafe status.
16.2 Design Engineering Notes
(1) Heat is the major cause of shortening the life of these products. Avoid assembly and
use of the target equipment in conditions where the product’s temperature may exceed
the maximum allowable.
(2) Failure to do so may result in degrading of the product’s functions and damage to the
product.
(3) If pulses or other transient loads (a large load applied in a short time) are applied to the
products, before use, check and evaluate their operation when assembled onto your
products.
(4) These products are not intended for other uses, other than under the special conditions
shown below. Before using these products under such special conditions, check their
performance and reliability under the said special conditions carefully, to determine
whether or not they can be used in such a manner.