DIALOG® ® 3G USER’S FCC ID: NTAXMETER21 WATER
Overview _____________________________________________________________________________________________ 1 Document Contents Overview___________________________________________________________________________ 1 Documentation Conventions ____________________________________________________________________________ 1 Documentation ______________________________________________________________________________________ 1 Conventions____________________________________________________________________________________
Product Return ______________________________________________________________________________________ 1 Document Ideas & Suggestions _________________________________________________________________________ 1 Product Return ______________________________________________________________________________________ 1 Document Ideas & Suggestions _________________________________________________________________________ 1 3
Before You Begin The DIALOG® 3G endpoint (DTMW) is an RF transceiver used to communicate metered consumption data in Automatic Meter Reading (AMR) systems. 3G features an exclusive design that completely encapsulates the encoder electronics, transceiver, antenna, and batteries under the register glass. A design called ConnectionFree™. Chapter Description Chapter 1. Getting Started Provides an overview of the DTMW endpoint installation, including installation options, siting, and required tools.
Cautionary Note on Repairs & Modifications ATTENTION!: Attempts to repair a 3G endpoint by unauthorized personnel (any one other than a Master Meter factory certified professional) may subject the person to shock hazard scenario if removal of protective covers is attempted. Unauthorized repair may void the warranty and/or maintenance contract with your company. ATTENTION!: This unit cannot be modified and is not repairable. Modification of this device could cause non-compliance with FCC rules.
General Admin Identification Trademark Notice Trademark Notice DTMW - 3G Endpoint Installation Guide 3G is a registered trademark of Master Meter, Inc. All other product names and logos in this document are used for identification purposes only and may be trademarks or registered trademarks of their respective companies. Patent Notice Patent Notice 3G intellectual property is protected by US and foreign patents, and/or patents pending.
Transportation Classification The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When activated, endpoints are considered operating transmitters and receivers and cannot be shipped by air. Product Return To comply with FCC, UN, and Department of Transportation regulations, all units must be returned in their original packaging following Master Meter’s Return Material Authorization (RMA) process.
About 3G The 3G endpoint for water is an AMR module fully integrated into the meter register that actively records consumption data, data logs this information, and provides a vigilant suite of Revenue Impact Alerts – Leak, Theft, Tamper, and Zero Consumption. P e r f o r m a n c e : Consumption data is sent continually every 11 seconds in the unlicensed 902-928 MHz bandwidth at 63 mW power. An integral Real Time Clock (RTC) ensures consistency in the transmission cycle.
Configurations: 3G endpoints may be installed in the following ways: • Installed on a new Master Meter product, or by retrofitting a standard register on an existing meter. • Retrofitting competitor products with the 3G Interpeter by swapping off the bayonet mounted standard register and replacing it with the 3G.
Included Materials The following materials are supplied by Master Meter: • Standard 3G register (figure 1) Figure 1 Materials not Included • Mechanical tools such as screwdrivers, pliers and wrenches are not provided by Master Meter. • Manual labor required to install or replace exiting registers and meter components is not included.
Installation Process Chart New Meter Application Turn off water service Remove existing –or– in case of new construction, install new meter equipped with 3G register Restore water service. Check for leaks. 3G’s auto-activation technology begins as soon as water flows through the meter and turns register gearing.
Installation Process Chart Retrofit Application Water service may remain on Remove existing standard Master Meter register Replace with new 3G Register 3G’s auto-activation technology begins as soon as water flows through the meter and turns register gearing.
Installation Process Chart Non-Master Meter Retrofit Application Water service may remain on Remove existing standard bayonet-mount register from meter bodyTransportation Classification Replace with new 3G Interpreter mounting ring. Be sure to use correct brand-specific ring for meter being retTransportation Classification Place 3G register inside ring and complete assembly with other housing pieces Insert locking pin in register housing to complete.
Associated FCC ID Devices FCC ID: NTADMMR1 – Rx & Tx from / to DTMW FCC ID: NTAMMR1 - Rx & Tx from / to DTMW FCC ID: NTAMMR2 – Rx from DTMW FCC ID: NTAMMR3 - Rx from DTMW FCC ID: NTAEMMR1 - Rx & Tx from / to DTMW FCC ID: NTALCRSA - Rx from DTMW 14