Brochure
1/114
5 5
5 5
Limit switches
OsiSense XC Standard, industrial format EN 50041
Metal, conforming to CENELEC EN 50041, type XCK J
Fixed or plug-in body. Adaptable sub-assemblies:
bodies with indicator light module
Fixed bodies with 2-pole contact
Type With contact
block
Scheme Positive
operation (1)
Cable entry Reference Weight
kg
With module comprising 1 LED, 24 V c
1 step NC + NO
snap action
(XE2S P2151)
Pg 13.5 ZCK J120 0.320
NC + NO
break before make,
slow break
(XE2N P2151)
Pg 13.5 ZCK J520 0.320
With module comprising 2 LEDs, 24 V c
1 step NC + NO
snap action
(XE2S P2151)
Pg 13.5 ZCK J121 0.320
ISO M20 x 1.5 ZCK J121H29 0.320
NC + NO
break before make,
slow break
(XE2N P2151)
Pg 13.5 ZCK J521 0.320
ISO M20 x 1.5 ZCK J521H29 0.320
With module comprising 2 LEDs, 110/240 V a
1 step
NC + NO
snap action
(XE2S P2151)
Pg 13.5 ZCK J134 0.320
ISO M20 x 1.5 ZCK J134H29 0.320
NC + NO
break before make,
slow break
(XE2N P2151)
Pg 13.5 ZCK J534 0.320
ISO M20 x 1.5 ZCK J534H29 0.320
Plug-in bodies with single-pole contact
Type With contact
block
Scheme Positive
operation (1)
Cable entry Reference Weight
kg
With module comprising 2 LEDs, 24 V c
1 step CO
snap action
– Pg 13.5 ZCK J1121 0.340
ISO M20 x 1.5 ZCK J1121H29 0.340
With module comprising 2 LEDs, 110/240 V a
1 step CO
snap action
– Pg 13.5 ZCK J1134 0.340
ISO M20 x 1.5 ZCK J1134H29 0.340
(1)
: NC contact with positive opening operation.
Indicator light module characteristics
Type of indicator 1 LED or 2 LEDs 2 LEDs
Rated insulation voltage 50 V c, conforming to IEC 60947-1 250 V a, conforming to IEC 60947-1
Current consumption 7 mA per LED 9 mA per LED
Rated operational voltage 24 V c 110/240 V a
Voltage limits 20…30 V c (including ripple) 95…264 V a
Service life 100 000 hours 100 000 hours
Reverse polarity protection Yes –
22 21
13
14
22 21
13
14
22 21
13
14
22 21
13
14
22 21
13
14
22 21
13
14
12 11
13
14
12 11
13
14
ZCKJppp
ZCKJ1
ppp
References
31161-EN_Ver1.0.indd
1
2
3
4
5
6
7
8
9
10