Brochure
5 5
1/101
5 5
Limit switches 3
OsiSense XC Standard
Industrial format EN 50041
Metal, type XCK J
Conforming to CENELEC EN 50041
Contact block characteristics
Rated operational
characteristics
XE2p P
a AC-15; A300 (Ue = 240 V, Ie = 3 A); Ithe = 10 A
c DC-13; Q300 (Ue = 250 V, Ie = 0.27 A), conforming to IEC 60947-5-1 Appendix A, EN 60947-5-1
XE3p P a AC-15; B300 (Ue = 240 V, Ie = 1.5 A); Ithe = 6 A
c DC-13; R300 (Ue = 250 V, Ie = 0.1 A), conforming to IEC 60947-5-1 Appendix A,
EN 60947-5-1
Rated insulation voltage XE2p P Ui = 500 V degree of pollution 3 conforming to IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
XE3p P Ui = 400 V degree of pollution 3 conforming to IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
Rated impulse withstand
voltage
XE2p P U imp = 6 kV conforming to IEC 60947-1, IEC 60664
XE3p P U imp = 4 kV conforming to IEC 60947-1, IEC 60664
Positive operation (depending on model)
NC contacts with positive opening operation conforming to IEC 60947-5-1 Appendix K, EN 60947-5-1
Resistance across terminals y 25 mΩ conforming to IEC 60255-7 category 3
Short-circuit protection XE2p P 10 A cartridge fuse type gG (gl)
XE3p P 6 A cartridge fuse type gG (gl)
Connection
(screw clamp terminals)
XE2S P21p1 Clamping capacity, min:1 x 0.34 mm
2
, max: 2 x 1.5 mm
2
XE2N P21p1 Clamping capacity, min:1 x 0.5 mm
2
, max: 2 x 2.5 mm
2
XCK J plug-in and XES P20p1 Clamping capacity, min:1 x 0.75 mm
2
, max: 2 x 1.5 mm
2
XE3N P and XE3S P Clamping capacity, min: 1 x 0.34 mm
2
, max: 1 x 1 mm
2
or 2 x 0.75 mm
2
Minimum actuation speed XE2S P21p1 and XE3S P: 0.01 m/minute
XE2N P21
p1 and XE3N P: 6 m/minute
Electrical durability Conforming to IEC 60947-5-1 Appendix C
Utilisation categories AC-15 and DC-13
Maximum operating rate: 3600 operating cycles/hour
Load factor: 0.5
b
b
b
b
XE2S P21
p1, XE2S P2141 XE2N P21p1 XCK J plug-in, XES P20p1
AC supply
50/60 Hz a
o inductive circuit
DC supply c Power broken in W for 5 million operating
cycles.
Power broken in W for 5 million operating
cycles.
Power broken in W for 5 million operating
cycles.
Voltage V 24 48 120 Voltage V 24 48 120 Voltage V 24 48 120
o
W 10 7 4
o
W 13 9 7
o
W 10 7 4
For XE2S P
p151 on a or c, NC and NO contacts simultaneously loaded to the values shown with reverse polarity.
XE3S P
pppp XE3N Ppppp
AC supply
50/60 Hz a
o inductive circuit
DC supply c Power broken in W for 5 million operating
cycles.
Power broken in W for 5 million operating
cycles.
Voltage V 24 48 120 Voltage V 24 48 120
o
W 3 2 1
o
W 4 3 2
Millions of operating cycles
Current in A
0.1
0.5
1
5
0.5 1 5 10
110 V
48 V
230/400 V
2 3 4
Ithe
24 V
0.5 1 2 3 4 5 10
0.1
0.2
0.5
1
5
2
4
3
Ithe
230 V
12/24/48 V
110 V
Millions of operating cycles
Current in A
Millions of operating cycles
Current in A
0.5 1 2 5 10
0.1
0.5
1
5
2
3
4
230 V
48 V
Ithe
12/24 V
3
4
110 V
0.1
0.5
1
5
0.5 1 5 10
110 V
48 V
230/400 V
2 3 4
Ithe
24 V
Millions of operating cycles
Current in A
Millions of operating cycles
Current in A
0.5 1 2 3 4 5 10
0.1
0.2
0.5
1
5
2
4
3
Ithe
230 V
110 V
12/24/48 V
General characteristics
(continued)
31161-EN_Ver1.0.indd
1
2
3
4
5
6
7
8
9
10