Datasheet

Product datasheet
Characteristics
XGCS491B201
Standalone panel smart antenna
Main
Range of product
OsiSense XG
Product or component type
Panel mounting smart antenna
RFID compact station name
XGCS
RFID frequency
13.56 MHz
Design
Diameter 22 mounting
Electrical connection
5 pin(s) 1 male connector M12
Outer dimension
40 x 40 x 40 mm
Product compatibility
RFID microchip Texas (Tag-it HFI)
RFID microchip Fujitsu (MB89R118 - MB89R119)
RFID microchip NXP (Mifare classic 1K/4K)
[Sn] nominal sensing distance
10...70 mm
[Us] rated supply voltage
24 V DC conforming to Protective Extra Low
Voltage
Complementary
Operating mode
Standalone
Type of output signal
Discrete
Discrete output function
1 NO
Discrete output type
PNP
Switching capacity in mA
300 mA (overload and short-circuit protection)
Associated tag type
Automatic detection of the type of tag
ISO 14443 standard tags
ISO 15693 standard tags
Supply voltage limits
19.2...29 V DC
Current consumption
< 60 mA
Status LED
1 LED (dual colour) for RFID communication
1 LED (dual colour) for output state
Tightening torque
< 2.2 N.m
Marking
CE
Product weight
0.057 kg
Environment
product certifications
CE
standards
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 300 330-1
ETSI EN 300 330-2
ambient air temperature for operation
-25...70 °C
ambient air temperature for storage
-40...85 °C
IP degree of protection
IP65 conforming to IEC 60529
vibration resistance
2 mm (f = 5...29.5 Hz) conforming to EN 60068-2-6
7 gn (f = 29.5...150 Hz) conforming to EN 60068-2-6
shock resistance
30 gn for 11 ms conforming to EN 60068-2-27
IK degree of protection
IK02 conforming to EN 50102
electromagnetic compatibility
Electrostatic discharge immunity test forcontact discharge ( level: 3) - test level 6 kV
conforming to IEC 61000-4-2
Electrostatic discharge immunity test forair discharge ( level: 3) - test level 8 kV
conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields ( level: 3) - test level 10 V/m conforming to IEC
61000-4-3
Electrical fast transient/burst immunity test forsignal ports ( level: 3) - test level 1 kV
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
1 / 3

Summary of content (3 pages)