Datasheet

The Essential Guide to Sensor Selection
© 2003 Schneider Electric All Rights Reserved
16
2/03
Osiprox Ind uctive Prox imity S ensors
Accessories
Osiprox
Inductive Proximity Sensors _ Standard
Type J (8 x 22) Type F (15 x 32) Type E (26 x 26) Type C (40 x 40)
Nominal Sensing Distance Sn 2.5 mm 5 mm 10 mm 15 mm
Usable sensing distance (mm) 0...2 0...4 0…8 0…12
For flush mounting in metal shielded shielded shielded shielded
Enclosure M (metal) P (plastic) P P P P
Temperature range °F (°C) - 13...158 (- 25…70) - 13...158 (- 25…70) - 13...158 (- 25…70) - 13...158 (- 25…70)
Degree of protection (conforming to IEC 60 529) pre-cabled: IP68 (with connector: IP67)
Sensors for DC applications a (3-wire)
Connection: pre-cabled PvR (2 m)
Dimensions (mm) Ø x L or H x W x L 8 x 8 x 22 8 x 15 x 32 26 x 26 x 13 40 x 40 x 15
3-wire
PNP NO XS7J1A1PAL2 XS7F1A1PAL2 XS7E1A1PAL2 XS7C1A1PAL2
PNP NC XS7J1A1PBL2 XS7F1A1PBL2 XS7E1A1PBL2 XS7C1A1PBL2
NPN NO XS7J1A1NAL2 XS7F1A1NAL2 XS7E1A1NAL2 XS7C1A1NAL2
NPN NC XS7J1A1NBL2 XS7F1A1NBL2 XS7E1A1NBL2 XS7C1A1NBL2
Connection: M8 (1) or M12 connector
3-wire
PNP NO XS7J1A1PAL01M8 (2) XS7F1A1PAL01M8 (2) XS7E1A1PAM8 XS7C1A1PAM8
PNP NC XS7J1A1PBL01M8 (2) XS7F1A1PBL01M8 (2) XS7E1A1PBM8 XS7C1A1PBM8
NPN NO XS7J1A1NAL01M8 (2) XS7F1A1NAL01M8 (2) XS7E1A1NAM8 XS7C1A1NAM8
NPN NC XS7J1A1NBL01M8 (2) XS7F1A1NBL01M8 (2) XS7E1A1NBM8 XS7C1A1NBM8
Supply voltage limits min/max (V) including ripple 10...36 10...36 10...36 10...36
Switching capacity, max (mA) 100 100 100 100
Overload and Short-circuit protection () / LED output state indication () / / / /
Voltage drop, closed state (V) at I nominal 2 2 2 2
Switching frequency (Hz) 2000 2000 1000 1000
Sensors for AC or DC applications c / a (2-wire)
Connection: pre-cabled PvR (2 m)
Dimensions (mm) Ø x L or H x W x L 8 x 8 x 22 8 x 15 x 32 26 x 26 x 13 40 x 40 x 15
2-wire non-polarized
NO XS7J1A1DAL2 XS7F1A1DAL2 XS7E1A1DAL2 XS7C1A1DAL2
NC XS7J1A1DBL2 XS7F1A1DBL2 XS7E1A1DBL2 XS7C1A1DBL2
Connection: M8 or M12 connector
2-wire non-polarized
NO XS7J1A1DAL01M8 (2) XS7F1A1DAL01M8 (2) XS7E1A1DAM8 XS7C1A1DAM8
NC XS7J1A1DBL01M8 (2) XS7F1A1DBL01M8 (2) XS7E1A1DBM8 XS7C1A1DBM8
Supply voltage limits min/max (V) including ripple on DC 10...36 10...36 10...36 10...36
Switching capacity, max (mA) 100 100 100 100
Overload and Short-circuit protection () / LED output state indication () / / / /
Residual current, open state (mA) 0.5 0.5 0.5 0.5
Voltage drop, closed state (V) at I nominal 4 4 4 4
Switching frequency (Hz) AC / DC 4000 5000 1000 1000
(1) M8 not Snap-C
®
compatible (2) Pigtail cable (L = 0.15 m) with M8 connector
For flat sensors, forms J, F, E, C and D
straight 90°
Adaptor plate for
block type sensors
XSE / XSC / XSD
Mounting bracket with indexing pin for cylindrical sensors
M8 XSZB108
Type J XSZBJ00 XSZBJ90
Type F XSZBF00 XSZBF90
Type E XSZBE00 XSZBE90 XSZBE10 M12 XSZB112
Type C XSZBC00 XSZBC90 XSZBC10 M18 XSZB118
Type D XSZBD00 XSZBD10 M30 XSZB130
flush mountable in metal
Sna
p
-
C
®
com
p
atibl
e
Sna
p
-
C
®
com
p
atibl
e

Summary of content (2 pages)