Photo-electric sensors 1
OsiSense XU, general purpose, multimode
function
Compact design 50 x 50
5-wire AC or DC, 1 CO relay output
Characteristics
Sensor type XUK pppppM12 XUK pppppL2
Product certications UL, CSA, e
Connection M12 connector Pre-cabled, length: 2 m
Sensing distance
nominal Sn / maximum
(excess gain = 2) (excess gain = 1)
m 0.28 / 0.28 without accessory (diffuse with background suppression)
m 0.8 / 1.2 without accessory (diffuse)
m 4 / 5.7 with reector (polarised reex)
m 30 / 35 with transmitter for thru-beam function (thru-beam)
Type of transmission Infrared, except polarised reex (red)
Degree of protection Conforming to IEC 60529 IP 65, double insulation i
Storage temperature °C - 40…+ 70
Operating temperature °C - 25…+ 55
Materials Case PBT
Lens PMMA
Cable PvR
Vibration resistance Conforming to IEC 60068-2-6 7 gn, amplitude ± 1.5 mm (f = 10 to 55 Hz)
Shock resistance Conforming to IEC 60068-2-27 30 gn, duration 11 ms
Indicator lights Output state Yellow LED (transmission present for XUK 0ppppppT)
Supply on Green LED
Optical alignment aid/dirty Red LED (except for XUK 0ppppppT)
Alarm output mA y 50 with overload and short-circuit protection (except XUK 0ARCTp)
Rated supply voltage PNP/NPN V 12…24 c with protection against reverse polarity
Relay output V z 24…240
Voltage limits (including
ripple)
PNP/NPN V 10…36 c
Relay output V z 20…264
Current consumption, no-load PNP/NPN mA y 35; 20 for XUK 0AKppppT
Power consumption Relay output W 3 a or c
Switching capacity PNP/NPN mA y 100 with overload and short-circuit protection
Relay output A 3 a or c
Voltage drop, closed state V y 1.5
Time delay Relay output s 0…10 on-delay, off-delay, monostable
Maximum switching
frequency
PNP/NPN Hz 250 (200 for diffuse with background suppression)
Relay output Hz 20
Delays First-up ms < 200 (PNP/NPN); < 300 (relay output)
Response ms < 2 (PNP/NPN); < 25 (relay output) (< 2.5 for diffuse with background suppression)
Recovery ms < 2 (PNP/NPN); < 25 (relay output) (< 2.5 for diffuse with background suppression)
Wiring schemes
M12 connector Pre-cabled Receiver, PNP output Thru-beam transmitter c
3 (-)
1 (+)
4 OUT/Output
2 Alarm or beam
break input (1)
(-) BU (Blue)
(+) BN (Brown)
OUT/Output BK (Black)
Alarm/WH (White)
Beam break input (1)VI
(Violet)
Transmitter
Input 2/VI:
- not connected: beam made
- connected to –: beam broken
See connection on page 9/44
Pre-cabled, relay output Receiver, NPN output Thru-beam transmitter a Relay output
(1) Beam break input on thru-beam
transmitter only.
(z) BU (Blue)
(z) BN (Brown)
Relay common/GY (Grey)
NO BK (Black)
NC WH (White)
Transmitter
Detection curves
With thru-beam accessory (thru-beam) Without accessory (diffuse) Without accessory (diffuse
with background suppression)
With reector (polarised
reex)
Object 10 x 10 cm; 1 White 90%; 2 Grey 18% WithreectorXUZC50
Variation of usable sensing distance Su (without accessory, with adjustable background suppression)
Teach mode at minimum Teach mode at maximum A-B:objectreectioncoefcient
Black 6%
Grey 18%
White 90%
Sensing range
Non sensing zone (matt surfaces)
1 2
4 3
1 2
4 3
BN/1
BU/3
+
PNP
BK/4
WH/2
BN/1
BU/3
+
PNP
BK/4
WH/2
1/BN
3/BU
2/VI
1/BN
3/BU
2/VI
BN/1
BU/3
+
NPN
BK/4
WH/2
BN/1
BU/3
+
NPN
BK/4
WH/2
30
30
35
S
30
30
35
S
120 cm
80 cm
2
1
403
120 cm
80 cm
2
1
403
28 cm
28 cm
3
28 cm
28 cm
3
4
4
5,7
4
4
5,7
A
B
10
8,5
S (cm)
8,1
3
A
B
10
8,5
S (cm)
8,1
3
28
A
B
3823 S (cm)28
A
B
3823 S (cm)
Characteristics,
schemes,
curves