Datasheet
2
1
3
4
5
6
7
8
9
10
5/45
Photo-electric sensors 1
OsiSense XU, general purpose, single mode function
Compact design
Five-wire AC or DC, 1 CO relay output
Three-wire DC, solid-state output
Characteristics
Sensor type XUXpppppM12 XUX pANpNT16, pAPpNT16 XUXpARCpT16
Product certications UL, CSA, e
Connection M12 connector Screw terminals, ISO 16 cable gland
Sensing distance
nominal Sn / maximum
(excess gain = 2) (excess gain = 1)
m 2.1 / 3 diffuse with adjustable sensitivity
m 11 / 15 polarised reex with adjustable sensitivity
m 14 / 20 reex with adjustable sensitivity
m 40 / 60 thru-beam with adjustable sensitivity
Type of transmission Infrared, except polarised reex (red)
Degree of protection Conforming to IEC 60529 IP 65, IP 67, double insulation i
Storage temperature °C - 40…+ 70
Operating temperature °C - 25…+ 55
Materials Case PBT
Lens PMMA
Vibration resistance Conforming to IEC 60068-2-6 7 gn, amplitude ± 1.5 mm (f = 10 to 55 Hz)
Shock resistance Conforming to IEC 60068-2-27 30 gn, duration 11 ms
Indicator lights Output state Yellow LED (transmission present for XUX 0pppppppT c)
Supply on Green LED
Rated supply voltage PNP/NPN V 12…24 with protection against reverse polarity
Relay output V – 24…240 a or c
Voltage limits (including ripple) PNP/NPN V c 10...36
Relay output V – 20…264 a or c
Current consumption, no-load PNP/NPN mA y 35 (20 for XUX 0pppppppT)
Power consumption Relay output W – 2 a or c
Switching capacity PNP/NPN mA y 100 with overload and short-circuit protection
Relay output A – 500 000 operating cycles
3 A: cos j = 1/0.5 A: cos j = 0.4
Voltage drop, closed state V y 1.5
Maximum switching frequency PNP/NPN Hz 250
Relay output Hz – 20
Delays First-up ms < 15 (PNP/NPN); < 60 (relay output)
Response ms < 2 (PNP/NPN); < 25 (relay output)
Recovery ms < 2 (PNP/NPN); < 25 (relay output)
Wiring schemes
M12 connector Relay output z PNP/NPN c Transmitter c Transmitter z
See connection on page 9/44.
Terminals M12 Terminals M12 Terminals Terminals
1 z 1
p
1 + 1
p
1 + 1 z
2 z 3
p
2 - 3
p
2 - 2 z
3 NO 4
p
3 Output 2
p
3 Beam break input (1)
4 Relay common (1) Input not connected: beam made.
Input connected to –: beam broken.
5 NC
Maximum permissible conductor c.s.a.: 1 x 1.5 mm
2
or 1 x 0.75 mm
2
with cable end.
Detection curves
Thru-beam system Diffuse system Reex system Polarised reex system
Object 10 x 10 cm; 1 White 90%; 2 Grey 18%
WithreectorXUZC50 WithreectorXUZC50
Dimensions
XUXpppppT16 XUXpppppM12
1 2
4 3
1 2
4 3
-20
Ø 8 mm
40
20
40
80
-80
-40
60
20
m
cm
Sn 40 m
-20
Ø 8 mm
40
20
40
80
-80
-40
60
20
m
cm
Sn 40 m
Sn 2,1 m
-4
-2
2
6
4
0,7
3
cm
m
-6
0,05
2,10
Sn 2,1 m
-4
-2
2
6
4
0,7
3
cm
m
-6
0,05
2,10
5
10
15
-5
-10
-15
8
13 20
m
Sn 14 m
cm
0,05
5
10
15
-5
-10
-15
8
13 20
m
Sn 14 m
cm
0,05
m
5
10
15
-5
-10
-15
5
10 15
Sn 11 m
cm
0,05
m
5
10
15
-5
-10
-15
5
10 15
Sn 11 m
cm
0,05
(1) Elongated hole Ø 5.5 x 7
(2) Elongated hole Ø 5.5 x 9
(3) Ø 5.5 hole
(1) Elongated hole Ø 5.5 x 7
(2) Elongated hole Ø 5.5 x 9
(3) Ø 5.5 hole
M12
92
104
114
21
73
30
37
50
71
77
87
30,5
(3)
(2)
(1)
M12
92
104
114
21
73
30
37
50
71
77
87
30,5
(3)
(2)
(1)
Possible orientation of elbowed connector
(rear view)
Possible orientation of elbowed connector
(rear view)
Characteristics,
schemes,
curves,
dimensions
92
104
127
22
87
30
(3)
(2)
(1)
37
50
71
77
100