User's Manual

Section 6 - Wiring (Continued)
33
TABLE 2(B) TR12 2-SPEED PROGRAMMING DIAGRAM.
2-SPEED with DIRECTIONAL CONTROLS: ALL MOTIONS
MOTOR 1 CONNECTIONS MOTOR 2 CONNECTIONS MOTOR 3 CONNECTIONS
J4-3 HOIST UP J3-3 TROLLEY DIR 1 J2-3 BRIDGE DIR 1
J4-2 HOIST 2
ND
SPEED J3-2 TROLLEY 2
ND
SPEED J2-2 BRIDGE 2
ND
SPEED
J4-1 HOIST DOWN J3-1 TROLLEY DIR 2 J2-1 BRIDGE DIR 2
J4-4 HOT (J4-1, 2 & 3) J3-4 HOT (J3-1, 2 & 3) J2-4 HOT (J2-1, 2 & 3)
J5-6 HOIST DIR1/DIR2 J5-4 TROLLEY DIR1/DIR2 J5-2 BRIDGE DIR1/DIR2
J5-5 HOT HOIST DIR1/DIR2 J5-3 HOT TROLLEY DIR1/DIR2 J5-1 HOT BRIDGE DIR1/DIR2
NOTE
CHECK GOVERNMENTAL AND LOCAL REGULATIONS ON THE REQUIREMENTS OF HORNS OR ALARMS
BEFORE USING THIS CONFIGURATION, AS THERE IS NOT A SEPARATE ALARM CONTROL.
TRANSMITTER SWITCH SETTINGS
tele
Pilot
USE PDA SCREEN (Program the configuration switches 5, 6 & 7 to match the settings shown below).
MEMBRANE USE SW3 ā€œCā€
PENDANT, JLTX AND SLTX USE SW4 ā€œDā€
TRANSMITTER SWITCH SETTINGS: Position-5 Position -6 Position -7
ON OFF OFF
*NOTE: Hoist, Trolley and Bridge are listed here as traditional configurations, the installer may choose to define the
motors differently.
OFF
1 2 3 4 5 6 7 8
ON
For these switch
positions see
previous section.
Indicates Switch in OFF Position.
OUTPUTS
J2-3
J2-2
J2-1
B
RIDGE
*
MOTOR 3
1
ST
2
ND
Dir 1 Dir 2
OUTPUTS
J4-3
J4-2
J4-1
H
OIST
*
MOTOR 1
1
ST
2
ND
UP DN
2
ND
1
ST
2
ND
1
ST
OUTPUTS
J3-3
J3-2
J3-1
TROLLEY
*
MOTOR 2
1
ST
2
ND
Dir 1 Dir 2
2
ND
1
ST
J5-2J5-6 J5-4