User's Manual

Section 7 - Programming (Continued)
63
NOTE
ALWAYS REMEMBER TO STORE THE
PASSWORD IN A SECURE LOCATION FOR
ACCESS IF THE PASSWORD IS LOST OR
FORGOTTEN. ONCE THE TRANSMITTER IS PRO-
GRAMMED THERE IS NO WAY TO DEFEAT THE
PASSWORD WITHOUT USING A PDA TO EITHER
READ THE PASSWORD OUT OR REPROGRAM A
NEW ONE.
WARNING
THIS PASSWORD FUNCTION IS NOT TO BE USED
AS A SECURITY DEVICE. THE PURPOSE OF THIS
FUNCTION IS TO PREVENT ACCIDENTAL BANK
SWITCHING. THE BEST FORM OF SECURITY IS
ALWAYS TO LOCKUP THE TRANSMITTER WHEN
NOT IN SERVICE. FAILURE TO FOLLOW THIS
WARNING COULD RESULT IN SERIOUS INJURY
OR DEATH AND DAMAGE TO EQUIPMENT
.
The Bank password can be disabled during initial
programming by the PDA. To disable password
protection, tap the check in the box next to the phase
“Use bank password”. Disabling the Bank password is
not recommended unless the operator has access and
visibility to all possible cranes controlled.
WARNING
DISABLING THE PASSWORD FUNCTION IS PUTS
THE SYSTEM IN ACTIVE BANK SELECT. THIS
ALLOWS THE CRANE OPERATOR TO SWITCH
BETWEEN BANKS QUICKER. THE OPERATOR IN
THIS MODE MUST BE AWARE AND
RESPONSIBLE FOR ALL POSSIBLE CONTROLLED
CRANES. FAILURE TO FOLLOW THIS WARNING
COULD RESULT IN SERIOUS INJURY OR DEATH
AND DAMAGE TO EQUIPMENT
.
Bank Selection (At least one must be selected).
When done with the password section. Select the number
of Bank you wish to program and tap the cell labeled
with the appropriate Bank number.
The screen should switch to the Setup Bank screen
shown below. Complete the Bank setup as described
below and hit save. The PDA will revert to the initial
screen and the cell for the just programmed Bank should
darken and the word “on” appears. Tap on the cell
labeled with the next bank you wish to program and a
similar “Setup” screen to the one shown below will
appear. Continue doing this until you have programmed
the four Banks.
You do not have to use all Banks and you do not have to
use them in order.
Even after programming a Bank you can turn it back
“off”. A programmed Bank will not lose its
programming by turning it “off”. By turning ON and
OFF Banks you can easily save certain transmitter
configurations in the transmitter to turn them on at a later
time with the PDA without having to completely
reprogram them.
Bank Programming Setup Screen (Must select
system).
The number of the Bank will appear at the top of the
screen.
Before selecting any programming feature
first go to “System” and select the system type
. Tap
on the “System" arrow and select 10K, 9000, 9001, 9100
or 9101 type system. The TR12 Receiver is a 10K type
system. If you are unsure of the type of system you have
refer to the cover of the systems operating manual for the
appropriate system or call your Telemotive
representative. After selecting system type, your
programming screen will change to match the type of
system selected.
Bank 1 Bank 2 Bank 3 Bank 4
offoff off off
System 10K Freq AK01
Setup Bank #
A1
Receiver access code
1
0
B1
1
0
Multibox
Auto Turn Off
S3-1
1
0
Timer
Switch conf.: H,T,B
Main/Aux Aux
Save
Cancel
10K
9000
9100
10K
9001
9101
1-SPD 2-SPD