User's Manual

CL865-DUAL Hardware User Guide
1vv0301104 Rev.1 2014-03-07
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 64 of 70
Mod. 0805 2011-07 Rev.2
14.2. Moisture sensibility
The level of moisture sensibility of the Product is “3” according with standard IPC/JEDEC J-
STD-020, take care of all the relative requirements for using this kind of components.
Moreover, the customer has to take care of the following conditions:
a) The shelf life of the Product inside of the dry bag must be 12 months from the bag seal date,
when stored in a non-condensing atmospheric environment of <40°C / 90% RH
b) Environmental condition during the production: <= 30°C / 60% RH according to
IPC/JEDEC J-STD-033A paragraph 5
c) The maximum time between the opening of the sealed bag and the reflow process must be
168 hours if condition b) “IPC/JEDEC J-STD-033A paragraph 5.2” is respected
d) Baking is required if conditions b) or c) are not respected
e) Baking is required if the humidity indicator inside the bag indicates 10% RH or more