2.2 Turning OFF the GC864
The turning off of the device can be done in three ways:
by software command (see GC864 Software User Guide)
by hardware shutdown
When the device is shut down by software command or by hardware shutdown, it issues to the
network a detach request that informs the network that the device will not be reachable any more.
2.2.1 Hardware shutdown
To turn OFF the GC864 the pad ON# must be tied low for at least 1 second and then released.
The same circuitry and timing for the power on shall be used.
The device shuts down after the release of the ON# pad.
TIP: To check if the device has powered off, the hardware line PWRCTL should be monitored.
When PWRCTL goes low, the device has powered off.
2.3 Hardware Unconditional Reboot
To unconditionally Reboot the GC864, the pad RESET# must be tied low for at least 200 milliseconds
and then released.
The maximum current that can be drained from the ON# pad is 0,15 mA.
A simple circuit to do it is:
NOTE: don't use any pull up resistor on the RESET# line nor any totem pole digital output.
Using pull up resistor may bring to latch up problems on the GC864 power regulator and
improper functioning of the module. The line RESET# must be connected only in open
collector configuration.