User's Manual

Table Of Contents
GC864 Hardware User Guide
1vv0300874 Rev.0 – 2010-01-25
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved. Page 16 of 64
NOTE:
RTS must be connected to the GND (on the module side) if flow control is not used.
NOTE:
If not used, almost all pins must be left disconnected. The only exceptions are the
following pins:
Pin Signal Function
1 VBATT Main power supply
2 VBATT Main power supply
3 VBATT Main power supply
4 VBATT Main power supply
5 GND Ground
6 GND Ground
7 GND Ground
46 GND Ground
25 C103/TXD Serial data input (TXD) from DTE
26 C104/RXD Serial data output to DTE
31 C105/RTS Input for Request to send signal (RTS) from DTE
53 ON/OFF* Input command for switching power ON or OFF (toggle command).
54 RESET* Reset input
23 RX_TRACE RX Data for debug monitor
24 TX_TRACE TX Data for debug monitor
47 SERVICE SERVICE connection
4.1.1. GC864-QUAD V2 / GC864-DUAL V2 Antenna Connector
The GC864-QUAD V2 / GC864-DUAL V2 module is equipped with a 50 RF connector
from Murata, GSC type P/N MM9329-2700B.
The counterpart suitable is Murata MXTK92 Type or MXTK88 Type.
Moreover, the GC864-QUAD V2 / GC864-DUAL V2 has the antenna pads on the back
side of the PCB. This allows the manual soldering of the coaxial cable directly on the
back side of the PCB. However, the soldering is not an advisable solution for a
reliable connection of the antenna.