4 Hardware Commands
4.1 Turning ON the GE865
To turn on the GE865 the pad ON# must be tied low for at least 1 seconds and then released.
The maximum current that can be drained from the ON# pad is 0,1 mA.
A simple circuit to do it is:
NOTE: don't use any pull up resistor on the ON# line, it is internally pulled up. Using pull up resistor may bring to
latch up problems on the GE865 power regulator and improper power on/off of the module. The line ON# must be
connected only in open collector configuration.
NOTE: In this document all the lines that are inverted, hence have active low signals are labeled with a name that
ends with”#" or with a bar over the name.
TIP: To check if the device has powered on, the hardware line PWRMON should be monitored. After 900ms the line
raised up the device could be considered powered on.
ON#
Power ON impulse
GND
R1
R2
Q1