The following table shows the average power consumption of BlueMod+S operating in the
peripheral device role.
VSUP = 3,0V, T
amb
= 25°C, all GPIO lines left open, SLCK: 32,768 kHz
Condition Note Slow
clock
SLCK
Current
Consumption
Unit
Tx power (dBm)
(8)
max (+4) min (-30)
I
Avg
I
Avg
Standby, Advertising on 3 channels, advertising interval: 1,28s, UICP
not active or serial interface up
(5)
internal
(7)
ext. sig.
ext. XTAL
tbd.
tbd.
1,2
tbd.
tbd.
1,2
mA
Standby, Advertising on 3 channels, advertising interval: 1,28s, UICP
active and serial interface down
(1)
internal
(7)
ext. sig.
ext. XTAL
tbd.
tbd.
28
tbd.
tbd.
9,5
µA
Connected, connection interval: 7,5 ms, no data traffic (2,3) (6) 2,2 1,95 mA
Connected, connection interval: 7,5 ms, data traffic 115 kbit/s at the
serial port, central to peripheral
(2)
(6) 5,2 4,7 mA
Connected, connection interval: 7,5 ms, data traffic 115 kbit/s at the
serial port, peripheral to central
(2)
(6) 3,4 3,2 mA
Connected, connection interval: 37,5ms, no data traffic (2,4)
internal
(7)
ext. sig.
ext. XTAL
tbd.
tbd.
1,4
tbd.
tbd.
1,4
mA
Connected, connection interval: 37,5ms, data traffic 115 kbit/s at the
serial port, peripheral to central
(2,4)
(6) 2,0 1,9 mA
(1)
UART-CTS#, IUR-IN#, UART-RXD driven to CMOS high level, all UART output lines left open
(2)
connection parameters are setup by the central device when connection is established
(3)
no data to be transmitted, central device sends an empty packet (80 bit) then peripheral device
answers (empty packet: 80 bit)
(4)
these are a typical connection parameters used by an iPhone, iPad or iPad mini device in the
central device role
(5)
UART-inputs connected to GND or VSUP; UART output lines left open
(6)
same current consumption w. internal or external slow clock
(7)
RC oscillator internal to nRF51822, periodically trimmed by S-device
(8)
Tx power as set by AT command
Table 15: Supply Current BLE Terminal I/O Profile, Peripheral Device Role