XT 210/640/730 GPRS Control Panel I N S T A L L M A N U A L Doc. - Ref. 230-XT Last modification date : June 2019 Firmware version : XLP.04.04.05.XXX and later www.videofied.
Introduction I N S T A L L M A N U A L Description The XT is a fully wireless alarm system. It can be powered by standalone batteries or connected to a power supply. This panel is intended mainly for residential and commercial markets. With the Motion Viewers™ and Videofied® range of products, the XT panel provides video verification in case of intrusion. The XT panel has three wired programmable inputs and two wired programmable outputs.
Summary I N S T A L L M A N U A L Introduction............................................................................................................2 Summary...................................................................................................3 1. XT Panel setup...................................................................................................4 1.1 SIM card installation...............................................................................................4 1.
1. XT Panel setup I N S T A L L M A N U A L 1.1 SIM Card Installation Before removing the front cover from its box, Put the SIM card on the plastic base (Take care to respect the right direction). DO NOT insert or remove the SIM card while the panel is powered. 1.2 Panel mounting Fix the back casing on the wall using the three mounting holes as shown. Mounting the panel is not required for programming. Bracket holes www.videofied.
1. XT Panel setup I N S T A L L M A N U A L 1.3 Powering and initialization • • • The panel is powered either with a mains power supply with 4 backup LR20 Alkaline batteries (Option 1 recommended) or with 4 LSH20 Lithium batteries (Option 2). Press and hold the PROGRAMMING BUTTON for 10 seconds, until the indicator LED blinks twice. The panel is now reset, a CMA, XMA or XMB has to be enrolled to configure the panel.
1. XT Panel setup I N S T A L L M A N U A L 1.4 Pairing the remote keypad • Press the XT programming button and release for the enrollment of a programming keypad. • Insert all LS14500 Lithium batteries into the keypad. • Do not mount the keypad. It will display one of the following screens: RSI (c) 2013 videofied.com or <=========XX=========> • Press on both CLR and ESC NO keys at the same time and release. The indicator LED on the keypad will blink rapidly. Wait for the keypad to pair.
2. XTENDER Mode I N S T A L L M A N U A L The XT panel can be used as standard standalone alarm system but it can also be connected to an existing alarm system capable of latching a 9-12Vcc* voltage used for its arming/disarming. 2.1 Standalone Mode In this functioning mode, the XT panel works as a standard hybrid alarm system with 25 wireless peripherals and 3 programmable inputs. It is a totally standalone alarm system. 2.
3. XT Panel Programming I N S T A L L Keypad Display M A N U A L Actions and comments KEYPAD 1 RECORDED OK or YES < - LANGUAGE : - > ENGLISH (UK) for language selection The system can also be programmed in: french, italian, german, dutch, spanish, swedish, portuguese, danish, czech and polish. The language can be changed at any time once the panel is programmed in the MAINTENANCE menu.
3. XT Panel Programming I N S T A L L Keypad display M A N U A L Actions and comments You may name the installer code using the Alphanumeric Keypad. CODE NAME : If using automatic setting (called installer default list), enter the name of the list. OK or YES Warning : If the wrong installers list name is used it cannot be set later, the system must be defaulted. Leaving the name blank by pressing ESC NO, it will be named ‘ACCESS 1’ by default.
3. XT Panel Programming I N S T A L L Keypad display M A N U A L Actions and comments PERIODIC TEST Test Periodicity: 1 hour, 12 hours, 24 hours, 48 hours, 7 days or no tests. PERIODIC TEST : 24 HOURS We suggest a 24 hours periodic test call. To select periodicity OK or YES TEST (hour) : 04: OK or YES TEST (minutes) : 04:15 OK or YES CODE/STATE MODIFICATION? OK or YES CODE/STATE MODIFICATION ESC NO ALARM: event transmitted upon occurrence.
3. XT Panel Programming I N S T A L L M A N U A L SERVER ADDRESSES ? OK or YES IP1 ADDRESS 0.0.0.0 DOMAIN NAME 1 PORT 1 888 ESC NO SERVER ADDRESSES ? ESC NO 2G3G PARAMETERS ? The IP1 address, Domain name 1 and/or Port 1 are provided by the monitoring station. Leave Port details at 888 unless otherwise instructed. Press OK or YES to enter/modify the parameter then OK or YES for validation.
3. XT Panel Programming I N S T A L L 2G3G LEVEL ? Once the 2G3G test completed, the keypad will display one of the following results : M A N U A L - A level between 0/5 and 5/5. OK or YES - A GPRS Error code (please see Chapter 6 : 2G3G errors codes and contact your technical support). TEST IN PROGRESS END = OK/YES If the screens shuts down, press any key to light it up except OK or YES, ESC NO or CLR. 2G3G LEVEL 5/5 The 2G3G level test can last several minutes.
3. XT Panel Programming I N S T A L L M A N U A L XTENDER mode configuration ARMING PROFILE : FROM THE HOST OK or YES MODE SLOW : The panel will arm each device one at a time saving battery life. This mode is recommended. ARMING MODE MODE : SLOW MODE : FAST MODE FAST : The panel will arm all devices at the same time. This mode increases significantly the battery consumption. OK or YES to choose the parameter.
3. XT Panel Programming I N S T A L L M A N U A L Each device has a unique programming button or a specific manipulation. Please refer to the Installation Sheet for the device you would like to program. RECORDING DEVICES PRESS PROGRAM BUTTON OF DEVICE Please check the radio level of each device on its final location. The result must be 8 out of 9 as a minimum (please refer to the Radio Range section, page 8 for further details).
4. XT features guide I N S T A L L M A N U A L 4.1 Get to Access level 4 Tue 29/10 DISARMED 11:23 LVL:1 ACCESS LEVEL 1 ACCESS LEVEL LEVEL : 1 OK or YES To unlock and get access to the installer level 4, you need to successively enter TWO codes (in any order) : • INSTALLER CODE (entered during intial programming) • USER CODE (Level3): the user must authorize the installer to get access to the configuration of his panel. ACCESS LEVEL LEVEL : 4 OK or YES BADGE OR CODE OK or YES 4.
4. XT features guide I N S T A L L M A N U A L 4.3 Arming and Siren Mode Configuration • Use the to go to menu : CONFIGURATION (LEVEL 4) > SPECIAL ARMING MODES > FULL ARM, SP1 or SP2 use direction arrows to select the arming mode you want to modify and OK / YES. • There are 3 different arming modes : FULL ARM : Arming of all areas and all devices. Use a badge or a user code and press OK / key on the CMA keypad.
4. XT features guide I N S T A L L M A N U A L 4.4 Manage badges and access codes Access Level Access Level Definition & Rights LVL 1 Standby Level LVL 2 Restricted USER level, where it is only possible to arm/disarm the system. USER level, where it is possible to arm/disarm the system, check the event log, test the devices. LVL 3 Modifications of the settings are not possible at this level. User Level 3 can create Level 2 or Level 3 access codes or badges.
4. XT features guide I N S T A L L M A N U A L Enter a new end user Badge/Code Delete an end user Badge/Code BADGES ACCESS CODES ENTER A BADGE/CODE Press twice on the right arrow OK or YES ENTER A BADGE/CODE DELETING BADGES/CODES OK or YES OK or YES BADGE OR CODE Badges/codes list Enter a 4-6 digit user code and Select badge/code then OK or YES OK or YES or present a badge in front of the reader until you hear the registration beep.
4. XT features guide I N S T A L L M A N U A L 4.5 Delete the keypad or any other device ACCESS LEVEL 4 CONFIGURATION OK or YES GENERAL PARAMETERS AREAS AND DEVICES OK or YES DEVICES OK or YES ADD A NEW DEVICE DEVICE CONFIGURATION OK or YES Devices list to select the device and press OK or YES A1 : KEYPAD KEYPAD 1 OK or YES DELETE OK or YES < = = = = XX = = = = > You can now remove the batteries from the device www.videofied.
4. XT features guide I N S T A L L 4.6 Read the event log M A N U A L EVENT LOG When user disarms the system, the keypad indicates the last event. OK or YES In case of the user needs to read the full log file, use the keypad to go in EVENT LOG, press OK or YES on SELECT LAST EVENTS and use arrow to list the events. SELECT LAST EVENTS OK or YES 15/10/13 11:29 MODIFIED PARAMET 15/10/13 11:10 SYSTEM DISARMED Press OK or YES for more information about an event 4.
4. XT features guide I N S T A L L M A N U A L 4.8 Golden rules 1 Area 1 is always delayed.When you register a keypad or a badge reader into an area, that area will automatically be delayed. 2 Never position a panel next to a high voltage electrical cabinet . 3 Press CLR to erase a typing mistake. 4 Never register the same device twice (delete from the system first). 5 Registration of up to 25 devices (including the keypad).
5. Transmitted Events List I N S T A L L M A N U A L The XT panel can be configured to enable or disable the transmission of events like alarms or defaults. The installer can modify the default sending settings for those events, although it will end the EN50131 standard compliance. These are the default transmitted events : DEVICE (intrusions) ALERT (Panic Buttons) PANEL LOW BATT. TAMPER DEVICE LOW BATT. PERIODIC TEST DURESS CODE FIRE MEDICAL ASSIST.
6. 2G3G Error Codes I N S T A L L M A N U A L IMPORTANT: The PIN of the SIM card has to be deactivated or 00000. The following is a list of error codes that can appear after the 2G3G test. In case of 2G3G (GPRS or LTE) errors during initial programming, we strongly suggest to continue with the installation and perform the 2G3G (GPRS or ) level test again once achieved. 2G3G LEVEL : ERROR XXX This error checklist is provided for information purposes only.
7. Technical Specifications and Security Notes I N S T A L L M A N U A L FCC Regulatory Information for USA and CANADA FCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI Video Technologies may void the FCC authorization to operate this equipment. FCC Part 15.105 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
7. Technical Specifications and Security Notes I N S T A L L M A N U A L Security notes / (FR) Notes de sécurité / (DE) Hinweise zur Sicherheit • • • • English Remove battery before any maintenance ! WARNING, there is a risk of explosion if a battery is replaced by an incorrect type! Observe polarity when setting up the batteries! Do not throw used batteries! Bring them to your installer or a collection point.