User's Manual

6.70.104 SS2000 / SS2200 Association Procedures 5/2010
Step One – Power the Thermostat
1. Apply Power to the unit
2. Set the Thermostat to “Learn” mode:
a. Lift the front cover to expose the front panel buttons.
b. Push the % button three times in a row.
c. The display will read 00
d. Press the Up Arrow until the display reads 02, then push the % button again. “2”
represents the command to associate Sensors.
e. The display will change to Learn Mode, showing -0 then any number from 0 to 9.
Figure 2: Thermostat in "Learn Mode"
f. The Thermostat will remain in Learn Mode for approximately 90 seconds.
Step Two – Initiate the Association
5. While the Thermostat remains in Learn Mode, Poke the sensor.
6. The Thermostat will display a character plus a number, as seen below. The number
indicates the relative strength of the RF signal from the Sensor, on a scale of 0
(lowest) to 9 (highest).