User's Manual

EcoWave
Installation
Guide
Telkonet,
Configuration
10200 W. Innovation Dr., Ste. 300
Revision 9
Milwaukee
, WI 53226
Page
11
(800) 380
-
9640
www.telkonet.com
Figure 9: Maintenance Learn Menu
With 1 Device Associated, In Learn Mode
9. Hold the “On / Off” button on the EcoAir until the EcoAir displays two digits on its screen. This may
take up to 10 seconds. The displayed digits will be the last two digits of the EcoInsight’s serial number.
10. Verify the larger number in the EcoInsight “Learn” menu has increased by one.
11. Press the Fan button on the EcoInsight twice to exit the Maintenance Menu. Association is complete.
Continue to Step 12.
Verify the Association
12. Activate heat mode on the EcoAir (exact steps will vary by EcoAir firmware).
13. Increase the set temperature above the current room temperature.
14. Verify the EcoInsight/EcoSource engages its HVAC unit’s heating mode.
15. Activate cool mode on the EcoAir (exact steps will vary by EcoAir firmware).
16. Decrease the set temperature below the current room temperature.
17. Verify the EcoInsight/EcoSource engages its HVAC unit’s cooling mode.
18. Change the fan speed on the EcoAir to high by pressing the “Fan” button until the High fan speed is
indicated.
19. Verify the EcoInsight/EcoSource engages its HVAC unit’s fan at the highest speed.
20. Configuration is complete.