3.3.3 Tools Selection
3.3.3.1 Factory Set Parameters
Factory Set Parameters are informational only. Factory authorization is required
for adjustment. This information is valuable to PT-210M users when Voice
Transmissions are enabled. The ID numbers assigned to the various sensors and
internally generated alarms are displayed. When a voice transmission is received,
the Message ID Number correlates to the following table:
3.3.3.2 Sensor Inhibit Parameters
The
Inhibit Parameters
specify a
shutdown period where the
sensor circuits
are
desensitized
immediately prior to a message
transmission, and remain
desensitized for the selected
amount of time after the end of
transmission.
The Inhibit period allows the RF
transmission energy to dissipate,
preventing false detections
caused by potential feedback
through the sensitive detection
processing circuit.