User's Manual

14 PB-007726 Rev - A
2005.07.04
3.5.1 Qualify Mode
In Qualify Mode, two physically different sensors must be triggered within the Qualify
Period before a qualify event will be transmitted. Eligible sensors are Seismic (Pedestrian
and Vehicle), Left, Right, Contact, and Serial. Check the enable box to activate Qualify
Mode.
Note: If a Seismic/Pedestrian detection is involved, the event transmitted will be
QUAL/PEDESTRIAN. If a Seismic/Vehicle detection is involved, the event transmitted
will be QUAL/VEHICLE. With all other combinations, the event transmitted will be
simply QUAL.
3.5.1.1 Qualify Period
When Qualify Mode is enabled, select the Qualify Time Period within which
two physically different sensors must trigger to generate a detection message.
The Qualify Period starts when the system is in Qualify Mode and activity is
detected on an enabled sensor. Before the Qualify Period expires, a detection must
occur on another (physically different) sensor in order for the qualify event to be
transmitted. The valid range for this parameter is 00:01 to 59:59 (minutes and
seconds).
3.5.2 Seismic Sensor Setup
3.5.2.1 Seismic Sensitivity
The Seismic Sensitivity control is used to adjust the
sensitivity of the SEISMIC (Pedestrian/Vehicle)
sensor. The sensitivity is adjustable from 1 (least
sensitive) to 5 (most sensitive). This setting is only
available when Pedestrian or Vehicle Detections are
enabled.
Note:
A setting of 3 is satisfactory for most
installations. Also note that high settings can trigger
false detections. Therefore, set the sensitivity only as
high as necessary to obtain the required coverage.