User's Manual

37 PB-007726 Rev - A
2005.07.04
4.5.5.1 Unit ID
The Unit ID establishes the PT-210Ms identity. All PT-210M transmissions
contain the Unit ID as well as other information to describe the nature of the
event. The Unit ID valid range is 0 to 8175.
4.5.5.2 Digital Frequency (MHz)
The Digital Frequency is used for transmitting messages in the EIDS digital
message format. The PT-210M frequency range is set at the factory and is
displayed following a read of the unit. Available PT-210M frequencies are
selected by tapping on the drop-down list control and selecting the desired
frequency. The PT-210M unit cannot transmit on any other frequency other than
the specific ones shown.
Note: If both digital and voice transmissions are desired, the user may elect to
transmit on the same or different frequencies.
4.5.5.3 Voice Frequency (MHz)
The Voice Frequency is used for transmitting messages in the synthesized voice
format. The PT-210M frequency range is set at the factory and is displayed
following a read of the unit. Available PT-210M frequencies are selectable by
tapping on the drop-down list control and selecting the desired frequency. The
PT-210M unit cannot transmit on any other frequency other than the specific ones
shown.
Note
: If both digital and voice transmissions are desired, the user may elect to
transmit on the same or different frequencies.
4.5.5.4 Transmit digital
The Transmit digital field establishes the number of times a message will be
transmitted using the EIDS digital format. The count is selectable from disable to
3 times. If the Digital Transmit Count is disabled, the PT-210M will not transmit
a digital message.
Note: If the Digital Transmit Count is other than disabled, and a Tamper
detection occurs, the Tamper event will be transmitted 3 times.